Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,520
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0560 # 10 Y:1999 | 10 | 1999 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $563 | $380 | Implemented |
UD0560 # 11 Y:1999 | 11 | 1999 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $494 | $0 | Implemented |
MO0246 # 01 Y:1999 | 01 | 1999 | INCREASE USE OF AUTOMATION | $31,680 | $7,000 | Implemented |
MO0246 # 02 Y:1999 | 02 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,027 | $8,072 | Implemented |
MO0246 # 03 Y:1999 | 03 | 1999 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $3,419 | $277 | Implemented |
MO0246 # 04 Y:1999 | 04 | 1999 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,019 | $40 | Implemented |
MO0246 # 05 Y:1999 | 05 | 1999 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $3,732 | $4,699 | Implemented |
MO0246 # 06 Y:1999 | 06 | 1999 | MINIMIZE WATER USAGE | $3,728 | $11,000 | Not Implemented |
MO0246 # 07 Y:1999 | 07 | 1999 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $1,320 | $0 | Implemented |
NC0156 # 01 Y:1999 | 01 | 1999 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $9,453 | $15,000 | Not Implemented |
NC0156 # 02 Y:1999 | 02 | 1999 | INSULATE BARE EQUIPMENT | $27,013 | $1,295 | Not Implemented |
NC0156 # 03 Y:1999 | 03 | 1999 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $461,046 | $1,000,000 | Implemented |
NC0156 # 04 Y:1999 | 04 | 1999 | RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING | $65,000 | $80,000 | Implemented |
NC0156 # 05 Y:1999 | 05 | 1999 | USE REACTIVE RINSING | $2,015 | $325 | Not Implemented |
AS0241 # 01 Y:1999 | 01 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,409 | $5,640 | Not Implemented |
AS0241 # 02 Y:1999 | 02 | 1999 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,122 | $1,420 | Implemented |
AS0241 # 03 Y:1999 | 03 | 1999 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $571 | $700 | Implemented |
AS0241 # 04 Y:1999 | 04 | 1999 | INSTALL TIMERS AND/OR THERMOSTATS | $132 | $225 | Implemented |
AS0241 # 05 Y:1999 | 05 | 1999 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $16,449 | $7,556 | Not Implemented |
AS0241 # 06 Y:1999 | 06 | 1999 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $1,241 | $120 | Implemented |
AS0241 # 07 Y:1999 | 07 | 1999 | MODIFY PROCESS TO REDUCE MATERIAL USE/COST | $81,150 | $9,280 | Not Implemented |
HO0190 # 01 Y:1999 | 01 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,715 | $15,311 | Not Implemented |
HO0190 # 02 Y:1999 | 02 | 1999 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $9,478 | $39,600 | Not Implemented |
HO0190 # 03 Y:1999 | 03 | 1999 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $39,503 | $85,000 | Not Implemented |
HO0190 # 04 Y:1999 | 04 | 1999 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $7,524 | $2,500 | Implemented |