Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
6,403
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0505 # 04 Y:1996 | 04 | 1996 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $7,221 | $500 | Implemented |
UD0505 # 05 Y:1996 | 05 | 1996 | RECOVER WASTE HEAT FROM EQUIPMENT | $4,110 | $6,000 | Implemented |
UD0505 # 06 Y:1996 | 06 | 1996 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $2,448 | $1,000 | Implemented |
UD0505 # 07 Y:1996 | 07 | 1996 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $1,640 | $0 | Implemented |
OR0284 # 01 Y:1996 | 01 | 1996 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $35,224 | $10,450 | Implemented |
OR0284 # 02 Y:1996 | 02 | 1996 | INSTALL / REPAIR INSULATION ON STEAM LINES | $1,074 | $516 | Implemented |
OR0284 # 03 Y:1996 | 03 | 1996 | INSULATE FEEDWATER TANK | $291 | $155 | Implemented |
OR0284 # 04 Y:1996 | 04 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $170 | $804 | Not Implemented |
OK0510 # 01 Y:1996 | 01 | 1996 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $16,000 | $7,960 | Not Implemented |
OK0510 # 02 Y:1996 | 02 | 1996 | INSTALL / REPAIR INSULATION ON STEAM LINES | $37 | $25 | Not Implemented |
OK0510 # 03 Y:1996 | 03 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $9,445 | $588 | Not Implemented |
OK0510 # 04 Y:1996 | 04 | 1996 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $12,303 | $0 | Not Implemented |
OK0510 # 05 Y:1996 | 05 | 1996 | USE PHOTOCELL CONTROLS | $340 | $113 | Not Implemented |
MS0071 # 01 Y:1996 | 01 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $19,052 | $47,376 | Not Implemented |
MS0071 # 02 Y:1996 | 02 | 1996 | USE SYNTHETIC LUBRICANT | $972 | $180 | Not Implemented |
MS0071 # 03 Y:1996 | 03 | 1996 | REDUCE VENTILATION AIR | $3,442 | $3,975 | Not Implemented |
MS0071 # 04 Y:1996 | 04 | 1996 | OPTIMIZE PLANT POWER FACTOR | $1,192 | $750 | Not Implemented |
MS0071 # 05 Y:1996 | 05 | 1996 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,017 | $2,926 | Not Implemented |
MS0071 # 06 Y:1996 | 06 | 1996 | RECOVER WASTE HEAT FROM EQUIPMENT | $4,751 | $13,574 | Not Implemented |
MS0071 # 07 Y:1996 | 07 | 1996 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $3,597 | $8,560 | Not Implemented |
MS0071 # 08 Y:1996 | 08 | 1996 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $9,720 | $0 | Not Implemented |
MS0071 # 09 Y:1996 | 09 | 1996 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $12,764 | $15,100 | Not Implemented |
MA0377 # 01 Y:1996 | 01 | 1996 | TREAT AND REUSE RINSE WATERS | $70,000 | $198,000 | Not Implemented |
MA0377 # 02 Y:1996 | 02 | 1996 | USE COOLING TOWER WATER INSTEAD OF REFRIGERATION | $6,407 | $3,770 | Not Implemented |
MA0377 # 03 Y:1996 | 03 | 1996 | PAY UTILITY BILLS ON TIME | $3,363 | $0 | Implemented |