Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
9,980
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0070 # 04 Y:1995 | 04 | 1995 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $1,081 | $1,115 | Implemented |
WV0070 # 05 Y:1995 | 05 | 1995 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $1,490 | $2,598 | Not Implemented |
WV0070 # 06 Y:1995 | 06 | 1995 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,381 | $1,000 | Not Implemented |
WV0070 # 07 Y:1995 | 07 | 1995 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,269 | $350 | Not Implemented |
WV0070 # 08 Y:1995 | 08 | 1995 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,743 | $500 | Implemented |
WV0070 # 09 Y:1995 | 09 | 1995 | USE SYNTHETIC LUBRICANT | $784 | $600 | Implemented |
WV0070 # 10 Y:1995 | 10 | 1995 | REDUCE OR ELIMINATE WASTE | $55,850 | $25,220 | Not Implemented |
UD0464 # 01 Y:1995 | 01 | 1995 | OPTIMIZE PLANT POWER FACTOR | $11,874 | $15,000 | Not Implemented |
UD0464 # 02 Y:1995 | 02 | 1995 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $2,302 | $0 | Not Implemented |
UD0464 # 03 Y:1995 | 03 | 1995 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,152 | $3,000 | Not Implemented |
UD0464 # 04 Y:1995 | 04 | 1995 | DISCONNECT BALLASTS | $2,831 | $460 | Not Implemented |
UD0463 # 01 Y:1995 | 01 | 1995 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $493 | $0 | Not Implemented |
UD0463 # 02 Y:1995 | 02 | 1995 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $4,512 | $12,000 | Not Implemented |
UD0463 # 03 Y:1995 | 03 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $13,335 | $16,387 | Not Implemented |
UD0460 # 01 Y:1995 | 01 | 1995 | OPTIMIZE PLANT POWER FACTOR | $41,888 | $30,000 | Implemented |
UD0460 # 02 Y:1995 | 02 | 1995 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $11,025 | $0 | Not Implemented |
UD0460 # 03 Y:1995 | 03 | 1995 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,416 | $3,000 | Not Implemented |
UD0460 # 04 Y:1995 | 04 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,670 | $5,216 | Implemented |
UD0460 # 05 Y:1995 | 05 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,312 | $4,077 | Implemented |
UD0462 # 01 Y:1995 | 01 | 1995 | OPTIMIZE PLANT POWER FACTOR | $3,052 | $9,500 | Not Implemented |
UD0462 # 02 Y:1995 | 02 | 1995 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $3,665 | $1,500 | Implemented |
UD0462 # 03 Y:1995 | 03 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $31,569 | $16,500 | Implemented |
UD0462 # 04 Y:1995 | 04 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,510 | $2,700 | Implemented |
UD0461 # 01 Y:1995 | 01 | 1995 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $28,758 | $45,000 | Implemented |
UD0461 # 02 Y:1995 | 02 | 1995 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $4,437 | $0 | Implemented |