IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

906

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
OR0374 # 02 Y:2000 02 2000 USE PHOTOCELL CONTROLS $2,537 $1,000 Not Implemented
OR0374 # 03 Y:2000 03 2000 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $5,481 $18,298 Implemented
OR0374 # 04 Y:2000 04 2000 USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION $145 $500 Not Implemented
OR0369 # 01 Y:2000 01 2000 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $1,963 $8,640 Not Implemented
OR0369 # 02 Y:2000 02 2000 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $199 $0 Not Implemented
OR0369 # 03 Y:2000 03 2000 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $200 $850 Not Implemented
OR0369 # 04 Y:2000 04 2000 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $610 $4,000 Implemented
OR0369 # 05 Y:2000 05 2000 OPTIMIZE PLANT POWER FACTOR $732 $5,000 Not Implemented
OR0368 # 01 Y:2000 01 2000 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $18,890 $30,000 Not Implemented
OR0368 # 02 Y:2000 02 2000 REPLACE HEAT TREATING OVEN WITH MORE EFFICIENT UNIT $43,540 $401,460 Not Implemented
OR0368 # 03 Y:2000 03 2000 USE OPTIMUM SIZE AND CAPACITY EQUIPMENT $10,000 $4,040 Implemented
OR0368 # 04 Y:2000 04 2000 ADD ADDITIONAL PRODUCTION SHIFT $5,000 $0 Implemented
OR0368 # 05 Y:2000 05 2000 REGRIND, REUSE, OR SELL SCRAP PLASTIC PARTS $1,515 $1,500 Not Implemented
OR0349 # 01 Y:1999 01 1999 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $40,560 $64,125 Implemented
OR0349 # 02 Y:1999 02 1999 REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES $36,220 $98,500 Not Implemented
OR0349 # 03 Y:1999 03 1999 UPGRADE CONVEYORS $18,725 $46,000 Not Implemented
OR0349 # 04 Y:1999 04 1999 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $13,088 $10,000 Implemented
OR0349 # 05 Y:1999 05 1999 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,171 $0 Not Implemented
OR0349 # 06 Y:1999 06 1999 UPGRADE CONTROLS ON COMPRESSORS $24,695 $2,840 Implemented
OR0349 # 07 Y:1999 07 1999 INCREASE USE OF AUTOMATION $179,000 $42,000 Not Implemented
OR0347 # 01 Y:1999 01 1999 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $11,755 $9,290 Not Implemented
OR0347 # 02 Y:1999 02 1999 UPGRADE CONTROLS ON COMPRESSORS $21,932 $6,000 Implemented
OR0347 # 03 Y:1999 03 1999 ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK $2,610,000 $93,000 Implemented
OR0347 # 04 Y:1999 04 1999 OPTIMIZE PRODUCTION LOT SIZES AND INVENTORIES $327,800 $87,400 Implemented
OR0236 # 01 Y:1995 01 1995 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $9,371 $35,317 Implemented