Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,520
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SF0172 # 11 Y:1999 | 11 | 1999 | USE IN-PROCESS RECYCLING WHENEVER POSSIBLE | $960 | $0 | Implemented |
SF0172 # 12 Y:1999 | 12 | 1999 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $10,400 | $0 | Implemented |
SF0172 # 13 Y:1999 | 13 | 1999 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $1,632 | $250 | Not Implemented |
SF0172 # 14 Y:1999 | 14 | 1999 | USE UTILITY CONTROLLED POWER MANAGEMENT | $138,720 | $11,500 | Implemented |
ND0338 # 01 Y:1999 | 01 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $278 | $120 | Implemented |
ND0338 # 02 Y:1999 | 02 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $289 | $480 | Implemented |
ND0338 # 03 Y:1999 | 03 | 1999 | INSTALL OCCUPANCY SENSORS | $1,986 | $1,600 | Not Implemented |
ND0338 # 04 Y:1999 | 04 | 1999 | USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING | $318 | $272 | Implemented |
ND0338 # 05 Y:1999 | 05 | 1999 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $506 | $800 | Not Implemented |
ND0338 # 06 Y:1999 | 06 | 1999 | TURN OFF EQUIPMENT WHEN NOT IN USE | $60 | $87 | Implemented |
ND0338 # 07 Y:1999 | 07 | 1999 | COVER OPEN TANKS | $292 | $400 | Not Implemented |
ND0338 # 08 Y:1999 | 08 | 1999 | DEVELOP A REPAIR/REPLACE POLICY | $7,559 | $18,073 | Not Implemented |
ND0340 # 01 Y:1999 | 01 | 1999 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $9,628 | $0 | Not Implemented |
ND0340 # 02 Y:1999 | 02 | 1999 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $329 | $240 | Implemented |
ND0340 # 03 Y:1999 | 03 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $297 | $40 | Not Implemented |
ND0340 # 04 Y:1999 | 04 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $351 | $510 | Not Implemented |
ND0340 # 05 Y:1999 | 05 | 1999 | CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS | $134 | $500 | Not Implemented |
ND0340 # 06 Y:1999 | 06 | 1999 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $20 | $0 | Implemented |
ND0340 # 07 Y:1999 | 07 | 1999 | DEVELOP A REPAIR/REPLACE POLICY | $151 | $677 | Not Implemented |
MS0143 # 01 Y:1999 | 01 | 1999 | USE SYNTHETIC LUBRICANT | $2,471 | $825 | Not Implemented |
MS0143 # 02 Y:1999 | 02 | 1999 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $405 | $0 | Not Implemented |
MS0143 # 03 Y:1999 | 03 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,411 | $1,101 | Not Implemented |
MS0143 # 04 Y:1999 | 04 | 1999 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $5,726 | $12,791 | Not Implemented |
MS0143 # 05 Y:1999 | 05 | 1999 | INSTALL TIMERS AND/OR THERMOSTATS | $477 | $708 | Not Implemented |
NC0172 # 01 Y:1999 | 01 | 1999 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $125,000 | $52,000 | Not Implemented |