Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
162,359
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
KU0179 # 05 Y:1985 | 05 | 1985 | COVER OPEN TANKS | $279 | $60 | Implemented |
KU0179 # 06 Y:1985 | 06 | 1985 | REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED | $174 | $0 | Implemented |
KU0180 # 01 Y:1985 | 01 | 1985 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $13,925 | $10,798 | Not Implemented |
KU0180 # 02 Y:1985 | 02 | 1985 | INSTALL TIMERS AND/OR THERMOSTATS | $3,940 | $400 | Implemented |
KU0180 # 03 Y:1985 | 03 | 1985 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $3,326 | $0 | Implemented |
KU0180 # 04 Y:1985 | 04 | 1985 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $175 | $128 | Not Implemented |
KU0180 # 05 Y:1985 | 05 | 1985 | IMPROVE LUBRICATION PRACTICES | $618 | $1,155 | Not Implemented |
KU0180 # 06 Y:1985 | 06 | 1985 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $412 | $50 | Not Implemented |
KU0180 # 07 Y:1985 | 07 | 1985 | INSULATE BARE EQUIPMENT | $265 | $416 | Not Implemented |
KU0180 # 08 Y:1985 | 08 | 1985 | INSULATE BARE EQUIPMENT | $148 | $220 | Not Implemented |
KU0180 # 09 Y:1985 | 09 | 1985 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $206 | $700 | Implemented |
KU0180 # 10 Y:1985 | 10 | 1985 | ADD AIR SHIELDS TO TRUCKS TO INCREASE FUEL MILEAGE | $127 | $0 | Not Implemented |
AT0022 # 04 Y:1985 | 04 | 1985 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $272 | $250 | Implemented |
AT0022 # 05 Y:1985 | 05 | 1985 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $830 | $450 | Implemented |
AT0022 # 06 Y:1985 | 06 | 1985 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $2,293 | $1,920 | Implemented |
AT0022 # 07 Y:1985 | 07 | 1985 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,564 | $205 | Implemented |
AT0023 # 01 Y:1985 | 01 | 1985 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $93 | $255 | Not Implemented |
AT0023 # 02 Y:1985 | 02 | 1985 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $127 | $270 | Not Implemented |
AT0023 # 03 Y:1985 | 03 | 1985 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,249 | $218 | Not Implemented |
AT0023 # 04 Y:1985 | 04 | 1985 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $156 | $250 | Implemented |
AT0023 # 05 Y:1985 | 05 | 1985 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $341 | $125 | Not Implemented |
AT0023 # 06 Y:1985 | 06 | 1985 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $3,785 | $2,700 | Implemented |
AT0024 # 01 Y:1985 | 01 | 1985 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $29 | $70 | Not Implemented |
AT0024 # 02 Y:1985 | 02 | 1985 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $111 | $0 | Implemented |
AT0024 # 03 Y:1985 | 03 | 1985 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $187 | $162 | Not Implemented |