Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

159,725

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
OK0084 # 08 Y:1983 08 1983 MINIMIZE OPERATION OF EQUIPMENT MAINTAINED IN STANDBY CONDITION $332 $45 Not Implemented
OK0085 # 01 Y:1983 01 1983 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $331 $198 Not Implemented
OK0085 # 02 Y:1983 02 1983 INSTALL TIMERS AND/OR THERMOSTATS $661 $642 Implemented
OK0085 # 03 Y:1983 03 1983 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE $437 $1,445 Implemented
OK0085 # 04 Y:1983 04 1983 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $422 $1,500 Implemented
OK0088 # 01 Y:1983 01 1983 REPLACE PURCHASED STEAM WITH OTHER ENERGY SOURCE $2,343 $5,600 Not Implemented
OK0088 # 02 Y:1983 02 1983 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $147 $292 Not Implemented
OK0088 # 03 Y:1983 03 1983 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $82 $70 Not Implemented
OK0088 # 04 Y:1983 04 1983 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $960 $2,170 Not Implemented
OK0088 # 05 Y:1983 05 1983 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $1,224 $2,000 Not Implemented
UD0086 # 01 Y:1983 01 1983 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,108 $480 Implemented
UD0086 # 02 Y:1983 02 1983 USE DEMAND CONTROLLER OR LOAD SHEDDER $1,175 $3,300 Implemented
UD0086 # 03 Y:1983 03 1983 REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED $204 $0 Implemented
UD0086 # 04 Y:1983 04 1983 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $139 $30 Implemented
UD0087 # 01 Y:1983 01 1983 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,289 $305 Not Implemented
UD0087 # 02 Y:1983 02 1983 TURN OFF EQUIPMENT WHEN NOT IN USE $647 $0 Not Implemented
UD0087 # 03 Y:1983 03 1983 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $1,975 $6,000 Not Implemented
KU0086 # 01 Y:1983 01 1983 INSTALL TIMERS AND/OR THERMOSTATS $4,657 $1,500 Not Implemented
KU0086 # 02 Y:1983 02 1983 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $2,333 $146 Not Implemented
KU0086 # 03 Y:1983 03 1983 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $866 $0 Not Implemented
KU0086 # 04 Y:1983 04 1983 INSTALL AUTOMATIC STACK DAMPER $489 $624 Not Implemented
KU0086 # 05 Y:1983 05 1983 INSTALL AUTOMATIC STACK DAMPER $489 $1,012 Not Implemented
KU0086 # 06 Y:1983 06 1983 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $427 $260 Not Implemented
KU0087 # 01 Y:1983 01 1983 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $6,398 $30,000 Implemented
KU0087 # 02 Y:1983 02 1983 OPTIMIZE PLANT POWER FACTOR $15,570 $15,000 Implemented