Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,520
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0171 # 01 Y:1999 | 01 | 1999 | ADJUST BURNERS FOR EFFICIENT OPERATION | $1,107 | $800 | Implemented |
NC0171 # 02 Y:1999 | 02 | 1999 | ADJUST BURNERS FOR EFFICIENT OPERATION | $35,782 | $800 | Implemented |
NC0171 # 03 Y:1999 | 03 | 1999 | RECOVER WASTE HEAT FROM EQUIPMENT | $4,918 | $4,000 | Implemented |
NC0171 # 04 Y:1999 | 04 | 1999 | INSULATE BARE EQUIPMENT | $877 | $300 | Implemented |
NC0171 # 05 Y:1999 | 05 | 1999 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $852 | $10 | Implemented |
NC0171 # 06 Y:1999 | 06 | 1999 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $213 | $400 | Not Implemented |
NC0171 # 07 Y:1999 | 07 | 1999 | DEVELOP STANDARD PROCEDURES TO IMPROVE INTERNAL YIELDS | $90,000 | $7,500 | Not Implemented |
NC0171 # 08 Y:1999 | 08 | 1999 | $143,173 | $137,600 | Not Implemented | |
CO0447 # 01 Y:1999 | 01 | 1999 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $2,160 | $5,000 | Implemented |
CO0447 # 02 Y:1999 | 02 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,270 | $660 | Implemented |
CO0447 # 03 Y:1999 | 03 | 1999 | REMOVE ROLLERS FROM THE MACHINES AND CLEAN IN A CLOSED SOLVENT CLEANER | $2,250 | $1,100 | Not Implemented |
CO0447 # 04 Y:1999 | 04 | 1999 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $170 | $0 | Not Implemented |
CO0447 # 05 Y:1999 | 05 | 1999 | REPLACE OLD MACHINE WITH NEW AUTOMATIC MULTI-STATION TOOL | $80,060 | $200,000 | Implemented |
CO0447 # 06 Y:1999 | 06 | 1999 | OPTIMIZE PRODUCTION LOT SIZES AND INVENTORIES | $29,130 | $30,000 | Not Implemented |
AR0168 # 01 Y:1999 | 01 | 1999 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,016 | $608 | Implemented |
AR0168 # 02 Y:1999 | 02 | 1999 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $223 | $0 | Implemented |
AR0168 # 03 Y:1999 | 03 | 1999 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $11,649 | $7,750 | Not Implemented |
AR0168 # 04 Y:1999 | 04 | 1999 | ELIMINATE/REDUCE REDUNDANT INSPECTIONS | $21,008 | $100 | Not Implemented |
NC0170 # 01 Y:1999 | 01 | 1999 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,515 | $0 | Implemented |
NC0170 # 02 Y:1999 | 02 | 1999 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,345 | $500 | Not Implemented |
NC0170 # 03 Y:1999 | 03 | 1999 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,462 | $2,000 | Implemented |
NC0170 # 04 Y:1999 | 04 | 1999 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $2,763 | $200 | Not Implemented |
NC0170 # 05 Y:1999 | 05 | 1999 | USE DISTILLATION, EVAPORATION TO REMOVE CONTAMINANTS | $29,116 | $20,000 | Not Implemented |
NC0170 # 06 Y:1999 | 06 | 1999 | MINIMIZE WATER USAGE | $3,900 | $50 | Not Implemented |
MO0263 # 01 Y:1999 | 01 | 1999 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,337 | $100 | Implemented |