Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
3,703
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
IA0519 # 06 Y:2014 | 06 | 2014 | INSTALL SPECTRAL REFLECTORS / DELAMP | $496 | $105 | Implemented |
BD0447 # 01 Y:2014 | 01 | 2014 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $3,951 | $20,000 | Not Implemented |
BD0447 # 02 Y:2014 | 02 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,465 | $7,100 | Not Implemented |
BD0447 # 03 Y:2014 | 03 | 2014 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $2,852 | $5,000 | Not Implemented |
BD0447 # 04 Y:2014 | 04 | 2014 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,048 | $2,790 | Not Implemented |
BD0447 # 05 Y:2014 | 05 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $811 | $200 | Not Implemented |
BD0447 # 06 Y:2014 | 06 | 2014 | INSTALL OCCUPANCY SENSORS | $608 | $1,500 | Not Implemented |
BD0447 # 07 Y:2014 | 07 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $478 | $350 | Not Implemented |
BD0447 # 08 Y:2014 | 08 | 2014 | USE PHOTOCELL CONTROLS | $444 | $435 | Not Implemented |
BD0447 # 09 Y:2014 | 09 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,206 | $3,300 | Not Implemented |
BD0447 # 10 Y:2014 | 10 | 2014 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $197 | $20 | Not Implemented |
OR0632 # 01 Y:2014 | 01 | 2014 | IMPROVE COMBUSTION CONTROL CAPABILITY | $3,802 | $0 | Not Implemented |
OR0632 # 02 Y:2014 | 02 | 2014 | INSTALL OCCUPANCY SENSORS | $2,497 | $2,837 | Implemented |
OR0632 # 03 Y:2014 | 03 | 2014 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,285 | $0 | Not Implemented |
OR0632 # 04 Y:2014 | 04 | 2014 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $870 | $500 | Implemented |
OR0632 # 05 Y:2014 | 05 | 2014 | UPGRADE CONTROLS ON COMPRESSORS | $2,833 | $0 | Not Implemented |
OR0631 # 01 Y:2014 | 01 | 2014 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $11,360 | $250 | Implemented |
OR0631 # 02 Y:2014 | 02 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,168 | $5,544 | Not Implemented |
OR0631 # 03 Y:2014 | 03 | 2014 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,567 | $1,634 | Implemented |
OR0631 # 04 Y:2014 | 04 | 2014 | INSTALL / REPAIR INSULATION ON STEAM LINES | $800 | $417 | Implemented |
OR0630 # 01 Y:2014 | 01 | 2014 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $4,792 | $500 | Implemented |
OR0630 # 02 Y:2014 | 02 | 2014 | ADJUST BURNERS FOR EFFICIENT OPERATION | $1,503 | $1,500 | Implemented |
OR0630 # 03 Y:2014 | 03 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $29,588 | $175,982 | Implemented |
OR0630 # 04 Y:2014 | 04 | 2014 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,626 | $500 | Implemented |
OR0630 # 05 Y:2014 | 05 | 2014 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,074 | $6,924 | Not Implemented |