IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

4,708

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MI0045 # 05 Y:2002 05 2002 ADD AREA LIGHTING SWITCHES $2,961 $1,550 Not Implemented
IA0293 # 01 Y:2002 01 2002 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $7,150 $1,034 Implemented
IA0293 # 02 Y:2002 02 2002 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $2,893 $224 Implemented
IA0293 # 03 Y:2002 03 2002 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $1,458 $46 Not Implemented
IA0293 # 04 Y:2002 04 2002 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $4,332 $0 Not Implemented
IA0293 # 05 Y:2002 05 2002 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,111 $6,493 Not Implemented
IA0293 # 06 Y:2002 06 2002 INSTALL OCCUPANCY SENSORS $261 $333 Implemented
IA0293 # 07 Y:2002 07 2002 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,134 $0 Implemented
IA0293 # 08 Y:2002 08 2002 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $2,769 $41 Not Implemented
CO0506 # 01 Y:2002 01 2002 USE DEMAND CONTROLLER OR LOAD SHEDDER $7,510 $12,000 Not Implemented
CO0506 # 02 Y:2002 02 2002 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $3,150 $540 Not Implemented
CO0506 # 03 Y:2002 03 2002 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $432 $240 Not Implemented
CO0506 # 04 Y:2002 04 2002 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $680 $0 Not Implemented
CO0506 # 05 Y:2002 05 2002 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $1,240 $3,630 Not Implemented
CO0506 # 06 Y:2002 06 2002 CONTRACT A WOOD PALLET RECYCLING COMPANY $4,890 $0 Not Implemented
CO0506 # 07 Y:2002 07 2002 DISTILL CONTAMINATED SOLVENTS FOR REUSE $4,300 $5,420 Implemented
UF0303 # 01 Y:2002 01 2002 SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY $23,984 $1,074 Not Implemented
UF0303 # 02 Y:2002 02 2002 INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS $6,229 $358 Implemented
UF0303 # 03 Y:2002 03 2002 OPTIMIZE PLANT POWER FACTOR $5,340 $24,092 Implemented
UF0303 # 04 Y:2002 04 2002 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $10,157 $29,907 n/a
UF0303 # 05 Y:2002 05 2002 INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS $138,554 $77,000 Not Implemented
UF0303 # 06 Y:2002 06 2002 USE EVAPORATION TO CONCENTRATE MATERIAL $13,509 $4,995 Implemented
UF0303 # 07 Y:2002 07 2002 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $89,796 $0 Not Implemented
UF0303 # 08 Y:2002 08 2002 PAY UTILITY BILLS ON TIME $7,393 $0 Implemented
UD0649 # 01 Y:2002 01 2002 ADD/MODIFY EQUIPMENT TO IMPROVE DRYING PROCESS $72,080 $3,600 Not Implemented