Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,871
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UL0200 # 03 Y:1998 | 03 | 1998 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $4,112 | $200 | Not Implemented |
UL0200 # 04 Y:1998 | 04 | 1998 | INSULATE BARE EQUIPMENT | $661 | $1,128 | Not Implemented |
UL0200 # 05 Y:1998 | 05 | 1998 | OPTIMIZE PLANT POWER FACTOR | $8,870 | $2,300 | Not Implemented |
UL0200 # 06 Y:1998 | 06 | 1998 | USE BUILDING MATERIALS WHICH REQUIRE LESS ENERGY TO PRODUCE | $45,190 | $106,250 | Not Implemented |
UL0200 # 07 Y:1998 | 07 | 1998 | RECOVER METALS FROM SPENT SOLUTIONS AND RECYCLE | $19,940 | $90,000 | Not Implemented |
UL0200 # 08 Y:1998 | 08 | 1998 | CROSS-TRAIN PERSONNEL TO AVOID LOST TIME | $1,000,000 | $102,500 | Not Implemented |
UL0200 # 09 Y:1998 | 09 | 1998 | ADD ADDITIONAL PRODUCTION SHIFT | $21,000 | $10,000 | Not Implemented |
UL0196 # 01 Y:1998 | 01 | 1998 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $7,123 | $20 | Not Implemented |
UL0196 # 02 Y:1998 | 02 | 1998 | DEVELOP STANDARD PROCEDURES TO IMPROVE INTERNAL YIELDS | $10,845 | $13,500 | Not Implemented |
UL0196 # 03 Y:1998 | 03 | 1998 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $2,772 | $0 | Not Implemented |
UL0196 # 04 Y:1998 | 04 | 1998 | DEVELOP STANDARD PROCEDURES TO IMPROVE INTERNAL YIELDS | $100,000 | $10,000 | Not Implemented |
UL0197 # 01 Y:1998 | 01 | 1998 | OPTIMIZE PLANT POWER FACTOR | $8,627 | $8,912 | Not Implemented |
UL0197 # 02 Y:1998 | 02 | 1998 | INSTALL TIMERS AND/OR THERMOSTATS | $503 | $400 | Not Implemented |
UL0197 # 03 Y:1998 | 03 | 1998 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $938 | $20 | Not Implemented |
UL0197 # 04 Y:1998 | 04 | 1998 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $10,824 | $1,700 | Implemented |
UL0197 # 05 Y:1998 | 05 | 1998 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $7,512 | $0 | Implemented |
UL0197 # 06 Y:1998 | 06 | 1998 | WASH AND REUSE RAGS ON-SITE | $2,925 | $4,500 | Implemented |
UL0195 # 01 Y:1998 | 01 | 1998 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $7,850 | $20 | Not Implemented |
UL0195 # 02 Y:1998 | 02 | 1998 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $4,732 | $260 | Not Implemented |
UL0195 # 03 Y:1998 | 03 | 1998 | INSTALL TIMERS AND/OR THERMOSTATS | $6,368 | $800 | Not Implemented |
UL0195 # 04 Y:1998 | 04 | 1998 | SEPARATE AND RECYCLE SCRAP METAL TO FOUNDRY OR FOR SALE | $2,628 | $0 | Implemented |
UL0195 # 05 Y:1998 | 05 | 1998 | UTILIZE OTHER METHODS TO REMOVE CONTAMINANTS | $6,458,418 | $3,180,000 | Not Implemented |
UL0195 # 06 Y:1998 | 06 | 1998 | MINIMIZE WATER USAGE | $235,872 | $666,500 | Not Implemented |
UL0195 # 07 Y:1998 | 07 | 1998 | HIRE ADDITIONAL PERSONNEL TO REDUCE CHANGEOUT TIME | $70,000 | $0 | Implemented |
UL0195 # 08 Y:1998 | 08 | 1998 | CONDENSE OPERATION INTO ONE BUILDING | $105,000 | $300,000 | Implemented |