Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

4,776

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
TN0614 # 04 Y:1997 04 1997 USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL $4,875 $0 Implemented
TN0614 # 05 Y:1997 05 1997 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $340 $340 Not Implemented
TN0614 # 06 Y:1997 06 1997 INSTALL TIMERS AND/OR THERMOSTATS $320 $580 Not Implemented
TN0612 # 01 Y:1997 01 1997 DEVELOP STANDARD PROCEDURES TO IMPROVE INTERNAL YIELDS $65,520 $36,000 Not Implemented
TN0612 # 02 Y:1997 02 1997 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $2,210 $0 Not Implemented
TN0612 # 03 Y:1997 03 1997 ELIMINATE PRACTICE OF MIXING WASTE STREAMS $2,004 $0 Implemented
TN0612 # 04 Y:1997 04 1997 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,990 $0 Not Implemented
TN0612 # 05 Y:1997 05 1997 METER WASTE WATER $660 $235 Not Implemented
TN0612 # 06 Y:1997 06 1997 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $600 $220 Implemented
TN0612 # 07 Y:1997 07 1997 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT $250 $650 Not Implemented
TN0602 # 01 Y:1997 01 1997 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE $333,410 $0 Implemented
TN0602 # 02 Y:1997 02 1997 DEVELOP STANDARD PROCEDURES TO IMPROVE INTERNAL YIELDS $327,397 $0 Implemented
TN0602 # 03 Y:1997 03 1997 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $83,573 $108,500 Implemented
TN0602 # 04 Y:1997 04 1997 USE RADIANT HEATER FOR SPOT HEATING $96,084 $35,020 Implemented
TN0602 # 05 Y:1997 05 1997 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $16,339 $3,000 Implemented
TN0602 # 06 Y:1997 06 1997 ADD AREA LIGHTING SWITCHES $11,208 $13,340 Implemented
TN0602 # 07 Y:1997 07 1997 INSTALL TIMERS AND/OR THERMOSTATS $10,349 $2,016 Implemented
TN0602 # 08 Y:1997 08 1997 REUSE / RECYCLE/ SELL PAPER PRODUCTS $3,540 $8,288 Implemented
TN0603 # 01 Y:1997 01 1997 ELIMINATE OLD STOCK AND MODIFY INVENTORY CONTROL $31,860 $12,660 Implemented
TN0603 # 02 Y:1997 02 1997 ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK $31,200 $21,000 Implemented
TN0603 # 03 Y:1997 03 1997 SEPARATE AND RECYCLE SCRAP METAL TO FOUNDRY OR FOR SALE $30,580 $0 Not Implemented
TN0603 # 04 Y:1997 04 1997 USE AUTOMATIC CLEANING EQUIPMENT $18,020 $38,470 Not Implemented
TN0603 # 05 Y:1997 05 1997 USE RADIANT HEATER FOR SPOT HEATING $16,800 $19,100 Not Implemented
TN0603 # 06 Y:1997 06 1997 CONVERT TO AIR ASSISTED / AIRLESS PAINT GUNS $8,550 $13,100 Not Implemented
TN0603 # 07 Y:1997 07 1997 INSTALL TIMERS AND/OR THERMOSTATS $840 $140 Not Implemented