IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

240

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
SF0223 # 06 Y:2001 06 2001 USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING $885 $900 Implemented
LM0018 # 02 Y:2001 02 2001 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $724 $350 Implemented
SF0223 # 12 Y:2001 12 2001 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $450,000 $50,000 Implemented
LM0018 # 04 Y:2001 04 2001 $7,800 $2,250 Implemented
SD0284 # 06 Y:2001 06 2001 UPGRADE CONTROLS ON COMPRESSORS $23,814 $1,000 Implemented
SD0284 # 10 Y:2001 10 2001 $69,350 $25,000 Implemented
SD0284 # 09 Y:2001 09 2001 USE FILTRATION, CENTRIFUGING TO REMOVE CONTAMINANTS $7,125 $2,000 Implemented
SD0284 # 01 Y:2001 01 2001 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $35,467 $2,580 Implemented
SF0223 # 05 Y:2001 05 2001 INSTALL OCCUPANCY SENSORS $1,304 $1,080 Implemented
SD0284 # 02 Y:2001 02 2001 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $16,645 $20,000 Implemented
SF0223 # 04 Y:2001 04 2001 INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS $4,914 $2,160 Implemented
SD0284 # 08 Y:2001 08 2001 TURN OFF EQUIPMENT WHEN NOT IN USE $30,429 $0 Implemented
SF0223 # 01 Y:2001 01 2001 TURN OFF EQUIPMENT WHEN NOT IN USE $16,905 $0 Implemented
SF0222 # 03 Y:2001 03 2001 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $17,737 $3,150 Implemented
SF0222 # 05 Y:2001 05 2001 INSTALL OCCUPANCY SENSORS $1,150 $2,400 Implemented
SF0222 # 04 Y:2001 04 2001 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $2,187 $2,939 Implemented
SF0222 # 01 Y:2001 01 2001 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $6,760 $0 Implemented
SF0221 # 02 Y:2001 02 2001 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $4,977 $480 Implemented
SF0221 # 01 Y:2001 01 2001 TURN OFF EQUIPMENT WHEN NOT IN USE $185 $0 Implemented
SF0221 # 10 Y:2001 10 2001 REUSE / RECYCLE/ SELL PAPER PRODUCTS $584 $80 Implemented
SF0221 # 08 Y:2001 08 2001 USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING $1,259 $1,259 Implemented
SF0221 # 03 Y:2001 03 2001 UPGRADE CONTROLS ON COMPRESSORS $2,046 $344 Implemented
LM0010 # 04 Y:2001 04 2001 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $2,507 $0 Implemented
LM0010 # 02 Y:2001 02 2001 INSTALL SPECTRAL REFLECTORS / DELAMP $3,603 $5,085 Implemented
LM0022 # 05 Y:2001 05 2001 $57,000 $102,000 Implemented