Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
78
matching recommendationsSIC | 265 | Paperboard Containers And Boxes |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
BD0212 # 09 Y:2002 | 09 | 2002 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $931 | $1,000 | Implemented |
BD0212 # 07 Y:2002 | 07 | 2002 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,219 | $600 | Implemented |
BD0212 # 05 Y:2002 | 05 | 2002 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $2,605 | $1,100 | Implemented |
BD0212 # 04 Y:2002 | 04 | 2002 | INSTALL OCCUPANCY SENSORS | $3,764 | $3,075 | Implemented |
BD0212 # 01 Y:2002 | 01 | 2002 | REPLACE BOILER | $17,844 | $70,000 | Implemented |
IC0029 # 07 Y:2002 | 07 | 2002 | INSULATE BARE EQUIPMENT | $1,616 | $906 | Implemented |
IC0029 # 06 Y:2002 | 06 | 2002 | USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER | $36,712 | $36,036 | Implemented |
IC0029 # 05 Y:2002 | 05 | 2002 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $14,179 | $1,500 | Implemented |
IC0029 # 04 Y:2002 | 04 | 2002 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $24,828 | $3,000 | Implemented |
IC0029 # 03 Y:2002 | 03 | 2002 | REPAIR AND ELIMINATE STEAM LEAKS | $10,646 | $900 | Implemented |
IC0029 # 01 Y:2002 | 01 | 2002 | INSULATE BARE EQUIPMENT | $1,907 | $3,610 | Implemented |
BD0201 # 11 Y:2002 | 11 | 2002 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $620 | $100 | Implemented |
BD0201 # 07 Y:2002 | 07 | 2002 | DISCONNECT BALLASTS | $653 | $240 | Implemented |
BD0201 # 03 Y:2002 | 03 | 2002 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,525 | $1,000 | Implemented |
WI0304 # 05 Y:1997 | 05 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,088 | $2,144 | Implemented |
WI0304 # 06 Y:1997 | 06 | 1997 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $600 | $0 | Implemented |
WI0304 # 02 Y:1997 | 02 | 1997 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $9,925 | $10,000 | Implemented |
WI0304 # 03 Y:1997 | 03 | 1997 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $7,517 | $500 | Implemented |
WI0278 # 12 Y:1996 | 12 | 1996 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,899 | $740 | Implemented |
WI0278 # 07 Y:1996 | 07 | 1996 | TURN OFF EQUIPMENT WHEN NOT IN USE | $5,818 | $0 | Implemented |
WI0278 # 09 Y:1996 | 09 | 1996 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $546 | $0 | Implemented |
WI0278 # 06 Y:1996 | 06 | 1996 | MINIMIZE WATER USAGE | $5,933 | $1,000 | Implemented |
WI0278 # 03 Y:1996 | 03 | 1996 | PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER | $11,230 | $500 | Implemented |
WI0278 # 02 Y:1996 | 02 | 1996 | INSTALL SET-BACK TIMERS | $15,919 | $2,400 | Implemented |
WI0278 # 11 Y:1996 | 11 | 1996 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $3,999 | $10,000 | Implemented |