Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

256

matching recommendations
Reset
SIC 33 Primary Metal Industries
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UK1312 # 09 Y:2013 09 2013 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $815 $0 Implemented
UK1312 # 10 Y:2013 10 2013 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $109,909 $9,000 Implemented
UK1312 # 11 Y:2013 11 2013 INSTALL REPLACEMENT DOORS $49,300 $270,900 Not Implemented
UK1312 # 12 Y:2013 12 2013 ADJUST BURNERS FOR EFFICIENT OPERATION $5,094 $8,500 Not Implemented
UK1312 # 13 Y:2013 13 2013 INSULATE BARE EQUIPMENT $4,473 $3,055 Not Implemented
UK1211 # 01 Y:2012 01 2012 UPGRADE CONTROLS ON COMPRESSORS $12,859 $11,250 Not Implemented
UK1211 # 02 Y:2012 02 2012 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $940 $420 Not Implemented
UK1211 # 03 Y:2012 03 2012 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $7,299 $7,500 Not Implemented
UK1211 # 04 Y:2012 04 2012 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $10,517 $30,800 Not Implemented
UK1211 # 05 Y:2012 05 2012 INSULATE BARE EQUIPMENT $10,493 $5,984 Not Implemented
UK1211 # 06 Y:2012 06 2012 PREHEAT COMBUSTION AIR WITH WASTE HEAT $14,200 $39,850 Not Implemented
UD0773 # 01 Y:2008 01 2008 UPGRADE CONTROLS ON COMPRESSORS $79,805 $20,000 Implemented
UD0773 # 02 Y:2008 02 2008 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $32,919 $21,000 Not Implemented
UD0773 # 03 Y:2008 03 2008 ENHANCE SENSITIVITY OF TEMPERATURE CONTROL AND CUTOFF $22,200 $15,000 Implemented
UD0773 # 04 Y:2008 04 2008 INSULATE BARE EQUIPMENT $16,500 $30,000 Not Implemented
UD0773 # 05 Y:2008 05 2008 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $15,532 $9,125 Not Implemented
UD0773 # 06 Y:2008 06 2008 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $10,125 $26,824 Not Implemented
UD0773 # 07 Y:2008 07 2008 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $9,990 $0 Implemented
UD0773 # 08 Y:2008 08 2008 SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY $4,322 $500 Not Implemented
UD0773 # 09 Y:2008 09 2008 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $2,733 $0 Not Implemented
UM0201 # 01 Y:2002 01 2002 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $972,000 $3,390,000 n/a
UM0201 # 02 Y:2002 02 2002 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $493,600 $1,060,000 n/a
UM0201 # 03 Y:2002 03 2002 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $519,147 $1,100,000 Not Implemented
UM0201 # 04 Y:2002 04 2002 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $76,800 $348,000 Not Implemented
UL0238 # 01 Y:2000 01 2000 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $6,743 $0 Not Implemented