Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
831
matching recommendationsSIC | 30 | Rubber And Miscellaneous Plastics Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0129 # 09 Y:1997 | 09 | 1997 | RECOVER AND REUSE COOLING WATER | $5,824 | $2,300 | Implemented |
UD0530 # 02 Y:1997 | 02 | 1997 | REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES | $3,250 | $5,600 | Implemented |
UD0530 # 04 Y:1997 | 04 | 1997 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $24,402 | $0 | Implemented |
UD0522 # 01 Y:1997 | 01 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,126 | $6,975 | Implemented |
UD0522 # 02 Y:1997 | 02 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $647 | $2,000 | Implemented |
UD0522 # 03 Y:1997 | 03 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,104 | $16,862 | Implemented |
UD0522 # 05 Y:1997 | 05 | 1997 | USE FLOW CONTROL VALVES ON EQUIPMENT TO OPTIMIZE WATER USE | $22,129 | $4,000 | Implemented |
UD0523 # 01 Y:1997 | 01 | 1997 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $34,683 | $0 | Implemented |
UD0523 # 02 Y:1997 | 02 | 1997 | REVISE RAW MATERIAL SPECS | $203,890 | $100,000 | Implemented |
UD0521 # 01 Y:1997 | 01 | 1997 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $7,099 | $0 | Implemented |
UD0521 # 02 Y:1997 | 02 | 1997 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $630 | $100 | Implemented |
UD0521 # 03 Y:1997 | 03 | 1997 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $868 | $1,000 | Implemented |
UD0521 # 06 Y:1997 | 06 | 1997 | UPGRADE OBSOLETE EQUIPMENT | $1,123 | $1,000 | Implemented |
WV0119 # 02 Y:1997 | 02 | 1997 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,860 | $345 | Implemented |
WV0119 # 03 Y:1997 | 03 | 1997 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,490 | $350 | Implemented |
WV0119 # 05 Y:1997 | 05 | 1997 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $617 | $500 | Implemented |
WV0119 # 06 Y:1997 | 06 | 1997 | REPAIR AND ELIMINATE STEAM LEAKS | $3,700 | $1,200 | Implemented |
WV0119 # 09 Y:1997 | 09 | 1997 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $7,136 | $16,305 | Implemented |
WV0119 # 10 Y:1997 | 10 | 1997 | CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS | $137,441 | $16,000 | Implemented |
WV0119 # 12 Y:1997 | 12 | 1997 | $11,020 | $30,000 | Implemented | |
UD0514 # 01 Y:1997 | 01 | 1997 | UPGRADE CONTROLS ON COMPRESSORS | $1,963 | $4,000 | Implemented |
UD0514 # 02 Y:1997 | 02 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,322 | $8,719 | Implemented |
UD0514 # 04 Y:1997 | 04 | 1997 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $756 | $2,099 | Implemented |
UD0514 # 07 Y:1997 | 07 | 1997 | UTILIZE SENSORS CONTROLLING ROOF AND WALL OPENINGS | $23,470 | $200 | Implemented |
UD0514 # 08 Y:1997 | 08 | 1997 | $71,600 | $21,000 | Implemented |