Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

71

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UD0299 # 04 Y:1989 04 1989 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $889 $750 Implemented
UD0298 # 01 Y:1989 01 1989 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $979 $2,250 Implemented
UD0299 # 02 Y:1989 02 1989 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $900 $0 Implemented
UD0299 # 05 Y:1989 05 1989 LOWER LIGHT FIXTURES IN HIGH CEILING AREAS $1,588 $1,720 Implemented
UD0299 # 03 Y:1989 03 1989 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $1,667 $750 Implemented
UD0294 # 01 Y:1989 01 1989 USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY $464 $0 Implemented
UD0291 # 05 Y:1989 05 1989 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $1,866 $2,000 Implemented
UD0290 # 04 Y:1989 04 1989 KEEP LAMPS AND REFLECTORS CLEAN $6,394 $11,600 Implemented
UD0292 # 02 Y:1989 02 1989 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,465 $233 Implemented
UD0291 # 02 Y:1989 02 1989 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $2,832 $15,000 Implemented
UD0291 # 03 Y:1989 03 1989 USE ONLY AMOUNT OF AIR NECESSARY TO PREVENT EXPLOSION HAZARD $851 $500 Implemented
UD0290 # 06 Y:1989 06 1989 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $2,146 $465 Implemented
UD0290 # 05 Y:1989 05 1989 REDUCE GLAZED AREAS IN BUILDINGS $22,077 $21,750 Implemented
UD0290 # 01 Y:1989 01 1989 COMBINE UTILITY METERS $2,104 $1,000 Implemented
UD0288 # 02 Y:1989 02 1989 REDUCE VENTILATION AIR $30,846 $10,000 Implemented
UD0288 # 05 Y:1989 05 1989 LOWER LIGHT FIXTURES IN HIGH CEILING AREAS $803 $0 Implemented
UD0288 # 03 Y:1989 03 1989 INSTALL / REPAIR INSULATION ON CONDENSATE LINES $23,159 $10,000 Implemented
UD0289 # 02 Y:1989 02 1989 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $2,453 $0 Implemented
UD0289 # 05 Y:1989 05 1989 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $356 $75 Implemented
UD0286 # 01 Y:1989 01 1989 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $6,690 $0 Implemented
UD0286 # 06 Y:1989 06 1989 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE $117,912 $60,000 Implemented
UD0286 # 08 Y:1989 08 1989 INSTALL TIMERS AND/OR THERMOSTATS $9,312 $0 Implemented
UD0286 # 02 Y:1989 02 1989 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $14,354 $0 Implemented
UD0286 # 03 Y:1989 03 1989 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $543 $0 Implemented
UD0286 # 05 Y:1989 05 1989 OPTIMIZE PLANT POWER FACTOR $6,809 $12,000 Implemented