Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
334
matching recommendationsSIC | 32 | Stone, Clay, And Glass Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AM0542 # 03 Y:2008 | 03 | 2008 | OPTIMIZE PLANT POWER FACTOR | $12,000 | $18,000 | Not Implemented |
AM0542 # 04 Y:2008 | 04 | 2008 | $6,925 | $0 | Not Implemented | |
AM0542 # 05 Y:2008 | 05 | 2008 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $1,500 | $0 | Implemented |
AM0526 # 02 Y:2007 | 02 | 2007 | OPTIMIZE PLANT POWER FACTOR | $15,310 | $65,120 | Not Implemented |
AM0526 # 10 Y:2007 | 10 | 2007 | USE SYNTHETIC LUBRICANT | $1,915 | $0 | Not Implemented |
AM0526 # 09 Y:2007 | 09 | 2007 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $3,080 | $2,850 | Not Implemented |
AM0526 # 08 Y:2007 | 08 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,545 | $2,300 | Not Implemented |
AM0526 # 07 Y:2007 | 07 | 2007 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $5,550 | $0 | Not Implemented |
AM0526 # 06 Y:2007 | 06 | 2007 | INSTALL SKYLIGHTS | $8,650 | $8,650 | Not Implemented |
AM0526 # 05 Y:2007 | 05 | 2007 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $10,500 | $0 | Not Implemented |
AM0526 # 04 Y:2007 | 04 | 2007 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $10,660 | $500 | Not Implemented |
AM0526 # 03 Y:2007 | 03 | 2007 | RE-SIZE CHARGING OPENINGS OR ADD A MOVABLE DOOR ON EQUIPMENT | $14,200 | $16,400 | Not Implemented |
AM0526 # 01 Y:2007 | 01 | 2007 | LOWER LIGHT FIXTURES IN HIGH CEILING AREAS | $29,900 | $18,130 | Not Implemented |
TA0080 # 01 Y:2004 | 01 | 2004 | REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES | $67,776 | $13,000 | Implemented |
TA0080 # 02 Y:2004 | 02 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $16,160 | $585 | Implemented |
TA0080 # 03 Y:2004 | 03 | 2004 | REPAIR AND ELIMINATE STEAM LEAKS | $7,900 | $875 | Implemented |
TA0080 # 04 Y:2004 | 04 | 2004 | INSTALL ADEQUATE DRYERS ON AIR LINES TO ELIMINATE BLOWDOWN | $3,990 | $1,600 | Implemented |
TA0080 # 05 Y:2004 | 05 | 2004 | INSTALL / REPAIR INSULATION ON STEAM LINES | $1,000 | $1,000 | Implemented |
AM0428 # 01 Y:2003 | 01 | 2003 | $13,600 | $4,000 | Implemented | |
AM0428 # 02 Y:2003 | 02 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,180 | $500 | Not Implemented |
AM0428 # 03 Y:2003 | 03 | 2003 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $2,020 | $0 | Implemented |
AM0424 # 01 Y:2003 | 01 | 2003 | USE ALTERNATIVE FLOCCULENT TO MINIMIZE SLUDGE VOLUME | $111,100 | $8,000 | Implemented |
AM0424 # 02 Y:2003 | 02 | 2003 | REPAIR OR REPLACE STEAM TRAPS | $55,000 | $730 | Implemented |
AM0424 # 03 Y:2003 | 03 | 2003 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $23,000 | $11,000 | Implemented |
AM0424 # 04 Y:2003 | 04 | 2003 | KEEP BOILER TUBES CLEAN | $5,720 | $500 | Implemented |