Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

334

matching recommendations
Reset
SIC 32 Stone, Clay, And Glass Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
AM0542 # 03 Y:2008 03 2008 OPTIMIZE PLANT POWER FACTOR $12,000 $18,000 Not Implemented
AM0542 # 04 Y:2008 04 2008 $6,925 $0 Not Implemented
AM0542 # 05 Y:2008 05 2008 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $1,500 $0 Implemented
AM0526 # 02 Y:2007 02 2007 OPTIMIZE PLANT POWER FACTOR $15,310 $65,120 Not Implemented
AM0526 # 10 Y:2007 10 2007 USE SYNTHETIC LUBRICANT $1,915 $0 Not Implemented
AM0526 # 09 Y:2007 09 2007 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $3,080 $2,850 Not Implemented
AM0526 # 08 Y:2007 08 2007 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,545 $2,300 Not Implemented
AM0526 # 07 Y:2007 07 2007 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $5,550 $0 Not Implemented
AM0526 # 06 Y:2007 06 2007 INSTALL SKYLIGHTS $8,650 $8,650 Not Implemented
AM0526 # 05 Y:2007 05 2007 USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL $10,500 $0 Not Implemented
AM0526 # 04 Y:2007 04 2007 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $10,660 $500 Not Implemented
AM0526 # 03 Y:2007 03 2007 RE-SIZE CHARGING OPENINGS OR ADD A MOVABLE DOOR ON EQUIPMENT $14,200 $16,400 Not Implemented
AM0526 # 01 Y:2007 01 2007 LOWER LIGHT FIXTURES IN HIGH CEILING AREAS $29,900 $18,130 Not Implemented
TA0080 # 01 Y:2004 01 2004 REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES $67,776 $13,000 Implemented
TA0080 # 02 Y:2004 02 2004 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $16,160 $585 Implemented
TA0080 # 03 Y:2004 03 2004 REPAIR AND ELIMINATE STEAM LEAKS $7,900 $875 Implemented
TA0080 # 04 Y:2004 04 2004 INSTALL ADEQUATE DRYERS ON AIR LINES TO ELIMINATE BLOWDOWN $3,990 $1,600 Implemented
TA0080 # 05 Y:2004 05 2004 INSTALL / REPAIR INSULATION ON STEAM LINES $1,000 $1,000 Implemented
AM0428 # 01 Y:2003 01 2003 $13,600 $4,000 Implemented
AM0428 # 02 Y:2003 02 2003 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $4,180 $500 Not Implemented
AM0428 # 03 Y:2003 03 2003 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $2,020 $0 Implemented
AM0424 # 01 Y:2003 01 2003 USE ALTERNATIVE FLOCCULENT TO MINIMIZE SLUDGE VOLUME $111,100 $8,000 Implemented
AM0424 # 02 Y:2003 02 2003 REPAIR OR REPLACE STEAM TRAPS $55,000 $730 Implemented
AM0424 # 03 Y:2003 03 2003 USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION $23,000 $11,000 Implemented
AM0424 # 04 Y:2003 04 2003 KEEP BOILER TUBES CLEAN $5,720 $500 Implemented