Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
110
matching recommendationsNAICS | 31182 | Cookie, Cracker, and Pasta Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SD0421 # 02 Y:2009 | 02 | 2009 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $35,684 | $50,000 | Implemented |
SD0421 # 05 Y:2009 | 05 | 2009 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $13,149 | $2,700 | Implemented |
SD0421 # 08 Y:2009 | 08 | 2009 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $568 | $1,444 | Implemented |
IC0156 # 01 Y:2009 | 01 | 2009 | ADD AREA LIGHTING SWITCHES | $10,860 | $8,096 | Implemented |
IC0156 # 02 Y:2009 | 02 | 2009 | INSTALL OCCUPANCY SENSORS | $4,252 | $4,247 | Implemented |
IC0156 # 03 Y:2009 | 03 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,116 | $1,649 | Implemented |
IC0156 # 04 Y:2009 | 04 | 2009 | DISCONNECT BALLASTS | $2,089 | $2,200 | Implemented |
IC0156 # 05 Y:2009 | 05 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $14,483 | $29,250 | Implemented |
IC0156 # 06 Y:2009 | 06 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,309 | $5,917 | Implemented |
IC0156 # 07 Y:2009 | 07 | 2009 | DEVELOP A REPAIR/REPLACE POLICY | $4,792 | $15,044 | Implemented |
IC0156 # 10 Y:2009 | 10 | 2009 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $934 | $0 | Implemented |
IC0156 # 11 Y:2009 | 11 | 2009 | INSTALL / REPAIR INSULATION ON STEAM LINES | $1,559 | $2,887 | Implemented |
IC0156 # 12 Y:2009 | 12 | 2009 | INSTALL TIMERS AND/OR THERMOSTATS | $1,299 | $0 | Implemented |
GT0861 # 03 Y:2009 | 03 | 2009 | ADJUST BURNERS FOR EFFICIENT OPERATION | $38,729 | $40,000 | Implemented |
GT0861 # 05 Y:2009 | 05 | 2009 | INSULATE BARE EQUIPMENT | $98,000 | $244,260 | Implemented |
GT0861 # 06 Y:2009 | 06 | 2009 | INSULATE BARE EQUIPMENT | $6,025 | $951 | Implemented |
NC0366 # 04 Y:2007 | 04 | 2007 | USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER | $71,297 | $280,000 | Implemented |
NC0366 # 05 Y:2007 | 05 | 2007 | INCREASE AMOUNT OF CONDENSATE RETURNED | $12,430 | $12,000 | Implemented |
IA0403 # 01 Y:2007 | 01 | 2007 | RECOVER WASTE HEAT FROM EQUIPMENT | $984 | $750 | Implemented |
IA0403 # 03 Y:2007 | 03 | 2007 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,132 | $25 | Implemented |
IA0403 # 04 Y:2007 | 04 | 2007 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $855 | $400 | Implemented |
IA0403 # 05 Y:2007 | 05 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,814 | $12,468 | Implemented |
IA0403 # 06 Y:2007 | 06 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,368 | $14,768 | Implemented |
UM0312 # 05 Y:2006 | 05 | 2006 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $1,885 | $2,250 | Implemented |
CO0586 # 02 Y:2006 | 02 | 2006 | INSULATE BARE EQUIPMENT | $1,790 | $890 | Implemented |