Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
106
matching recommendationsNAICS | 3131 | Fiber, Yarn, and Thread Mills |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0540 # 12 Y:2015 | 12 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $14,592 | $67,363 | Implemented |
MZ0082 # 02 Y:2012 | 02 | 2012 | OPTIMIZE PLANT POWER FACTOR | $18,500 | $17,720 | Implemented |
MZ0082 # 04 Y:2012 | 04 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,870 | $850 | Implemented |
UA0066 # 01 Y:2011 | 01 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $21,215 | $62,771 | Implemented |
UA0066 # 03 Y:2011 | 03 | 2011 | UPGRADE CONTROLS ON COMPRESSORS | $22,864 | $30,000 | Implemented |
UA0066 # 04 Y:2011 | 04 | 2011 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $6,677 | $640 | Implemented |
UA0066 # 05 Y:2011 | 05 | 2011 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $22,848 | $11,400 | Implemented |
UA0066 # 06 Y:2011 | 06 | 2011 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $98,887 | $13,568 | Implemented |
UA0066 # 10 Y:2011 | 10 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $13,963 | $3,900 | Implemented |
NC0424 # 02 Y:2011 | 02 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $30,681 | $112,768 | Implemented |
NC0424 # 03 Y:2011 | 03 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,430 | $4,435 | Implemented |
NC0424 # 04 Y:2011 | 04 | 2011 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $16,685 | $78,795 | Implemented |
NC0424 # 05 Y:2011 | 05 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,791 | $100 | Implemented |
GT0870 # 01 Y:2009 | 01 | 2009 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $625 | $0 | Implemented |
GT0870 # 03 Y:2009 | 03 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,245 | $20,050 | Implemented |
GT0870 # 04 Y:2009 | 04 | 2009 | INSTALL OCCUPANCY SENSORS | $5,810 | $620 | Implemented |
GT0870 # 05 Y:2009 | 05 | 2009 | USE SYNTHETIC LUBRICANT | $43,210 | $0 | Implemented |
GT0870 # 06 Y:2009 | 06 | 2009 | CHANGE ZONE REHEAT COILS TO VARIABLE AIR VOLUME BOXES | $1,500 | $6,399 | Implemented |
GT0870 # 07 Y:2009 | 07 | 2009 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $33,910 | $45,000 | Implemented |
GT0867 # 02 Y:2009 | 02 | 2009 | INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS | $8,794 | $4,000 | Implemented |
GT0867 # 03 Y:2009 | 03 | 2009 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $17,426 | $3,250 | Implemented |
GT0867 # 04 Y:2009 | 04 | 2009 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $14,518 | $6,000 | Implemented |
GT0867 # 06 Y:2009 | 06 | 2009 | USE SYNTHETIC LUBRICANT | $1,440 | $0 | Implemented |
GT0844 # 09 Y:2007 | 09 | 2007 | RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER | $323,139 | $174,963 | Implemented |
GT0828 # 02 Y:2006 | 02 | 2006 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $14,977 | $86,662 | Implemented |