Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
254
matching recommendationsNAICS | 331511 | Iron Foundries |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0692 # 05 Y:2004 | 05 | 2004 | COVER OPEN TANKS | $888 | $3,450 | Implemented |
UD0692 # 07 Y:2004 | 07 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $190 | $400 | Implemented |
IA0331 # 01 Y:2003 | 01 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $11,482 | $915 | Implemented |
IA0331 # 04 Y:2003 | 04 | 2003 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $2,662 | $3,125 | Implemented |
IA0331 # 05 Y:2003 | 05 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $614 | $586 | Implemented |
IA0331 # 06 Y:2003 | 06 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $755 | $1,738 | Implemented |
IA0331 # 07 Y:2003 | 07 | 2003 | INSTALL OCCUPANCY SENSORS | $203 | $599 | Implemented |
IA0331 # 08 Y:2003 | 08 | 2003 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,450 | $1,754 | Implemented |
IA0331 # 15 Y:2003 | 15 | 2003 | AUTOMATE PAYROLL SYSTEM | $9,200 | $12,500 | Implemented |
GT0759 # 01 Y:2003 | 01 | 2003 | COOL COMPRESSOR AIR INTAKE WITH HEAT EXCHANGER | $5,870 | $3,000 | Implemented |
GT0759 # 03 Y:2003 | 03 | 2003 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $33,765 | $188,200 | Implemented |
GT0759 # 07 Y:2003 | 07 | 2003 | USE RADIANT HEATER FOR SPOT HEATING | $5,960 | $2,190 | Implemented |
GT0759 # 08 Y:2003 | 08 | 2003 | RECOVER WASTE HEAT FROM EQUIPMENT | $89,620 | $108,930 | Implemented |
NC0254 # 02 Y:2003 | 02 | 2003 | INSTALL SENSORS TO DETECT DEFECTS | $85,500 | $3,000 | Implemented |
NC0254 # 03 Y:2003 | 03 | 2003 | MODIFY STARTUP/SHUTDOWN TIMES | $1,342,708 | $10,000 | Implemented |
NC0254 # 07 Y:2003 | 07 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,899 | $500 | Implemented |
OK0657 # 02 Y:2003 | 02 | 2003 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $2,220 | $25 | Implemented |
OK0657 # 03 Y:2003 | 03 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $10,257 | $320 | Implemented |
OK0657 # 08 Y:2003 | 08 | 2003 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $11,624 | $11,750 | Implemented |
BD0227 # 02 Y:2003 | 02 | 2003 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $6,495 | $0 | Implemented |
BD0227 # 03 Y:2003 | 03 | 2003 | USE RADIANT HEATER FOR SPOT HEATING | $4,490 | $7,000 | Implemented |
BD0227 # 04 Y:2003 | 04 | 2003 | INSTALL OCCUPANCY SENSORS | $2,617 | $450 | Implemented |
BD0227 # 07 Y:2003 | 07 | 2003 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $11,250 | $1,000 | Implemented |
BD0226 # 02 Y:2003 | 02 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $8,838 | $1,200 | Implemented |
BD0226 # 04 Y:2003 | 04 | 2003 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $740 | $0 | Implemented |