Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
326
matching recommendationsSIC | 228 | Yarn And Thread Mills |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
GT0757 # 03 Y:2003 | 03 | 2003 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $2,064 | $948 | Implemented |
GT0757 # 02 Y:2003 | 02 | 2003 | USE SYNTHETIC LUBRICANT | $12,742 | $0 | Implemented |
GT0757 # 01 Y:2003 | 01 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $732 | $450 | Implemented |
GT0739 # 02 Y:2002 | 02 | 2002 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,592 | $1,900 | Implemented |
GT0739 # 03 Y:2002 | 03 | 2002 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $6,450 | $50,177 | Implemented |
GT0739 # 05 Y:2002 | 05 | 2002 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $2,700 | $300 | Implemented |
GT0739 # 07 Y:2002 | 07 | 2002 | UPGRADE CONTROLS ON COMPRESSORS | $3,488 | $0 | Implemented |
GT0739 # 08 Y:2002 | 08 | 2002 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $658 | $500 | Implemented |
OD0172 # 03 Y:2000 | 03 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,087 | $1,800 | Implemented |
OD0172 # 01 Y:2000 | 01 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $89,664 | $154,663 | Implemented |
NC0202 # 01 Y:2000 | 01 | 2000 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $3,541 | $7,971 | Implemented |
NC0202 # 02 Y:2000 | 02 | 2000 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $9,464 | $865 | Implemented |
NC0202 # 03 Y:2000 | 03 | 2000 | CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE | $4,647 | $0 | Implemented |
NC0202 # 06 Y:2000 | 06 | 2000 | RECOVER AND REUSE COOLING WATER | $2,950 | $2,000 | Implemented |
NC0160 # 02 Y:1999 | 02 | 1999 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,043 | $2,000 | Implemented |
NC0160 # 04 Y:1999 | 04 | 1999 | INSTALL SKYLIGHTS | $1,207 | $2,000 | Implemented |
NC0160 # 06 Y:1999 | 06 | 1999 | ELIMINATE LEAKS IN WATER LINES AND VALVES | $1,045 | $1,550 | Implemented |
NC0160 # 07 Y:1999 | 07 | 1999 | ADOPT IN-HOUSE MATERIAL GENERATION | $49,559 | $100,000 | Implemented |
NC0160 # 01 Y:1999 | 01 | 1999 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $2,733 | $1,400 | Implemented |
NC0141 # 07 Y:1998 | 07 | 1998 | ELIMINATE LEAKS IN WATER LINES AND VALVES | $1,861 | $200 | Implemented |
NC0141 # 04 Y:1998 | 04 | 1998 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $31,048 | $4,000 | Implemented |
NC0141 # 03 Y:1998 | 03 | 1998 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $3,183 | $4,236 | Implemented |
NC0141 # 02 Y:1998 | 02 | 1998 | INSTALL ADEQUATE DRYERS ON AIR LINES TO ELIMINATE BLOWDOWN | $5,943 | $10,000 | Implemented |
NC0141 # 01 Y:1998 | 01 | 1998 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $556 | $60 | Implemented |
HO0161 # 01 Y:1997 | 01 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,362 | $11,311 | Implemented |