Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
46
matching recommendationsSIC | 229 | Miscellaneous Textile Goods |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0589 # 10 Y:2017 | 10 | 2017 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,050 | $100 | Implemented |
NC0589 # 09 Y:2017 | 09 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $541 | $300 | Implemented |
NC0589 # 08 Y:2017 | 08 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $29,155 | $66,186 | Implemented |
NC0589 # 07 Y:2017 | 07 | 2017 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,357 | $1,000 | Implemented |
NC0589 # 06 Y:2017 | 06 | 2017 | INSTALL / REPAIR INSULATION ON STEAM LINES | $3,876 | $840 | Implemented |
NC0576 # 01 Y:2016 | 01 | 2016 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $16,790 | $3,000 | Implemented |
NC0576 # 02 Y:2016 | 02 | 2016 | REPAIR OR REPLACE STEAM TRAPS | $108,434 | $80,000 | Implemented |
NC0407 # 01 Y:2010 | 01 | 2010 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $13,128 | $60,000 | Implemented |
NC0407 # 03 Y:2010 | 03 | 2010 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $3,606 | $1,000 | Implemented |
NC0407 # 04 Y:2010 | 04 | 2010 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $10,147 | $42,000 | Implemented |
NC0407 # 06 Y:2010 | 06 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,776 | $6,897 | Implemented |
NC0267 # 06 Y:2003 | 06 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $410 | $100 | Implemented |
NC0267 # 05 Y:2003 | 05 | 2003 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $3,004 | $12,000 | Implemented |
NC0267 # 04 Y:2003 | 04 | 2003 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $1,686 | $700 | Implemented |
NC0238 # 12 Y:2002 | 12 | 2002 | ESTABLISH A PREVENTATIVE MAINTENANCE PROGRAM | $4,536 | $1,500 | Implemented |
NC0238 # 06 Y:2002 | 06 | 2002 | REPAIR OR REPLACE STEAM TRAPS | $10,000 | $9,340 | Implemented |
NC0238 # 02 Y:2002 | 02 | 2002 | REPAIR AND ELIMINATE STEAM LEAKS | $3,389 | $5,000 | Implemented |
NC0238 # 01 Y:2002 | 01 | 2002 | ELIMINATE LEAKS IN WATER LINES AND VALVES | $1,890 | $2,100 | Implemented |
NC0238 # 11 Y:2002 | 11 | 2002 | DEVELOP A REPAIR/REPLACE POLICY | $6,185 | $17,736 | Implemented |
NC0238 # 10 Y:2002 | 10 | 2002 | INCREASE AMOUNT OF CONDENSATE RETURNED | $4,818 | $6,000 | Implemented |
NC0238 # 07 Y:2002 | 07 | 2002 | INSTALL / REPAIR INSULATION ON STEAM LINES | $1,112 | $2,405 | Implemented |
NC0238 # 13 Y:2002 | 13 | 2002 | RECOVER WASTE HEAT FROM EQUIPMENT | $93,319 | $15,000 | Implemented |
NC0158 # 08 Y:1999 | 08 | 1999 | REDUCE SCRAP PRODUCTION | $2,360 | $4,100 | Implemented |
NC0158 # 07 Y:1999 | 07 | 1999 | RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING | $5,794 | $2,500 | Implemented |
NC0158 # 04 Y:1999 | 04 | 1999 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $972 | $907 | Implemented |