Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

46

matching recommendations
Reset
SIC 229 Miscellaneous Textile Goods
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
NC0589 # 10 Y:2017 10 2017 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,050 $100 Implemented
NC0589 # 09 Y:2017 09 2017 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $541 $300 Implemented
NC0589 # 08 Y:2017 08 2017 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $29,155 $66,186 Implemented
NC0589 # 07 Y:2017 07 2017 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,357 $1,000 Implemented
NC0589 # 06 Y:2017 06 2017 INSTALL / REPAIR INSULATION ON STEAM LINES $3,876 $840 Implemented
NC0576 # 01 Y:2016 01 2016 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $16,790 $3,000 Implemented
NC0576 # 02 Y:2016 02 2016 REPAIR OR REPLACE STEAM TRAPS $108,434 $80,000 Implemented
NC0407 # 01 Y:2010 01 2010 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $13,128 $60,000 Implemented
NC0407 # 03 Y:2010 03 2010 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $3,606 $1,000 Implemented
NC0407 # 04 Y:2010 04 2010 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT $10,147 $42,000 Implemented
NC0407 # 06 Y:2010 06 2010 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,776 $6,897 Implemented
NC0267 # 06 Y:2003 06 2003 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $410 $100 Implemented
NC0267 # 05 Y:2003 05 2003 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $3,004 $12,000 Implemented
NC0267 # 04 Y:2003 04 2003 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $1,686 $700 Implemented
NC0238 # 12 Y:2002 12 2002 ESTABLISH A PREVENTATIVE MAINTENANCE PROGRAM $4,536 $1,500 Implemented
NC0238 # 06 Y:2002 06 2002 REPAIR OR REPLACE STEAM TRAPS $10,000 $9,340 Implemented
NC0238 # 02 Y:2002 02 2002 REPAIR AND ELIMINATE STEAM LEAKS $3,389 $5,000 Implemented
NC0238 # 01 Y:2002 01 2002 ELIMINATE LEAKS IN WATER LINES AND VALVES $1,890 $2,100 Implemented
NC0238 # 11 Y:2002 11 2002 DEVELOP A REPAIR/REPLACE POLICY $6,185 $17,736 Implemented
NC0238 # 10 Y:2002 10 2002 INCREASE AMOUNT OF CONDENSATE RETURNED $4,818 $6,000 Implemented
NC0238 # 07 Y:2002 07 2002 INSTALL / REPAIR INSULATION ON STEAM LINES $1,112 $2,405 Implemented
NC0238 # 13 Y:2002 13 2002 RECOVER WASTE HEAT FROM EQUIPMENT $93,319 $15,000 Implemented
NC0158 # 08 Y:1999 08 1999 REDUCE SCRAP PRODUCTION $2,360 $4,100 Implemented
NC0158 # 07 Y:1999 07 1999 RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING $5,794 $2,500 Implemented
NC0158 # 04 Y:1999 04 1999 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $972 $907 Implemented