Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

1,218

matching recommendations
Reset
SIC 242 Sawmills And Planing Mills
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
OR0419 # 02 Y:2002 02 2002 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $4,392 $5,000 Implemented
OR0419 # 03 Y:2002 03 2002 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $6,988 $3,240 Implemented
OR0419 # 05 Y:2002 05 2002 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $1,587 $0 Implemented
WV0242 # 01 Y:2002 01 2002 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $3,167 $0 Implemented
WV0242 # 03 Y:2002 03 2002 UTILIZE A LESS EXPENSIVE COOLING METHOD $7,620 $4,870 Implemented
WV0242 # 05 Y:2002 05 2002 RECOVER WASTE HEAT FROM EQUIPMENT $4,564 $128 Implemented
WV0242 # 06 Y:2002 06 2002 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $456 $72 Implemented
WV0242 # 07 Y:2002 07 2002 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $304 $0 Implemented
WV0242 # 08 Y:2002 08 2002 USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY $8,335 $900 Implemented
WV0242 # 10 Y:2002 10 2002 SEPARATE AND RECYCLE SCRAP METAL TO FOUNDRY OR FOR SALE $864 $400 Implemented
NC0236 # 02 Y:2002 02 2002 DEVELOP A REPAIR/REPLACE POLICY $4,419 $8,200 Implemented
NC0236 # 04 Y:2002 04 2002 USE PHOTOCELL CONTROLS $115 $260 Implemented
LL0141 # 01 Y:2002 01 2002 USE POWER DURING OFF-PEAK PERIODS $189,217 $0 Implemented
LL0141 # 02 Y:2002 02 2002 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $16,007 $2,985 Implemented
LL0141 # 04 Y:2002 04 2002 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $9,695 $1,485 Implemented
AM0413 # 02 Y:2002 02 2002 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $5,600 $1,000 Implemented
AM0413 # 03 Y:2002 03 2002 OPTIMIZE PLANT POWER FACTOR $5,000 $0 Implemented
AM0413 # 04 Y:2002 04 2002 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES $2,800 $5,600 Implemented
AM0413 # 05 Y:2002 05 2002 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $830 $400 Implemented
AM0413 # 08 Y:2002 08 2002 USE PHOTOCELL CONTROLS $230 $40 Implemented
WV0231 # 01 Y:2002 01 2002 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $3,654 $900 Implemented
WV0231 # 02 Y:2002 02 2002 OPTIMIZE PLANT POWER FACTOR $1,600 $156 Implemented
WV0231 # 07 Y:2002 07 2002 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $745 $12 Implemented
WV0231 # 08 Y:2002 08 2002 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $465 $900 Implemented
WV0231 # 09 Y:2002 09 2002 ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM $4,141 $460 Implemented