IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

364

matching recommendations
Reset
SIC 262 Paper Mills
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
LM0069 # 05 Y:2004 05 2004 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $417 $15 Implemented
LM0069 # 06 Y:2004 06 2004 INSTALL / REPAIR INSULATION ON STEAM LINES $1,600 $210 Implemented
LM0069 # 07 Y:2004 07 2004 REPAIR AND ELIMINATE STEAM LEAKS $4,998 $108 Implemented
LM0069 # 08 Y:2004 08 2004 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,274 $835 Implemented
LM0069 # 09 Y:2004 09 2004 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $2,301 $2,241 Implemented
LM0069 # 10 Y:2004 10 2004 SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY $6,358 $10,398 Implemented
LM0069 # 11 Y:2004 11 2004 PROVIDE PROPER MAINTENANCE OF MOTOR DRIVEN EQUIPMENT $1,588 $18 Implemented
LM0069 # 12 Y:2004 12 2004 USE WASTE HEAT WITH A CLOSED-CYCLE GAS TURBINE-GENERATOR SET TO COGENERATE ELECTRICITY AND HEAT $170,219 $0 Implemented
LM0069 # 16 Y:2004 16 2004 DEVELOP STANDARD OPERATING PROCEDURES $86,625 $14,470 Implemented
LM0069 # 17 Y:2004 17 2004 DEVELOP STANDARD OPERATING PROCEDURES $79,714 $5,400 Implemented
NC0270 # 01 Y:2003 01 2003 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $149,890 $50,000 Implemented
NC0270 # 04 Y:2003 04 2003 ADJUST BURNERS FOR EFFICIENT OPERATION $16,620 $1,000 Implemented
NC0270 # 05 Y:2003 05 2003 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $4,551 $0 Implemented
NC0270 # 06 Y:2003 06 2003 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $3,246 $2,400 Implemented
LM0059 # 02 Y:2003 02 2003 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $298 $120 Implemented
LM0059 # 08 Y:2003 08 2003 INSTALL EQUIPMENT TO MOVE PRODUCT $17,902 $10,000 Implemented
SU0140 # 04 Y:2002 04 2002 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $35,283 $64,018 Implemented
SU0140 # 05 Y:2002 05 2002 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $34,631 $14,250 Implemented
SU0140 # 06 Y:2002 06 2002 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $25,122 $700 Implemented
SU0140 # 08 Y:2002 08 2002 INSTALL / REPAIR INSULATION ON STEAM LINES $3,151 $8,733 Implemented
SU0140 # 09 Y:2002 09 2002 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $2,480 $0 Implemented
MA0518 # 04 Y:2002 04 2002 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $3,756 $4,000 Implemented
MA0518 # 05 Y:2002 05 2002 SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY $2,648 $1,250 Implemented
MA0518 # 06 Y:2002 06 2002 INSULATE FEEDWATER TANK $847 $1,000 Implemented
MA0488 # 02 Y:2001 02 2001 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $84,500 $1,500 Implemented