Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
471
matching recommendationsSIC | 295 | Asphalt Paving And Roofing Materials |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SF0387 # 08 Y:2010 | 08 | 2010 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,393 | $2,851 | Implemented |
SF0387 # 09 Y:2010 | 09 | 2010 | INSTALL OCCUPANCY SENSORS | $920 | $2,132 | Implemented |
SF0387 # 10 Y:2010 | 10 | 2010 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $1,160 | $3,840 | Implemented |
SF0387 # 11 Y:2010 | 11 | 2010 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $1,342 | $6,259 | Implemented |
AM0553 # 01 Y:2008 | 01 | 2008 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $80,000 | $960 | Implemented |
AM0553 # 02 Y:2008 | 02 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $24,080 | $1,500 | Implemented |
AM0553 # 04 Y:2008 | 04 | 2008 | OPTIMIZE PLANT POWER FACTOR | $19,840 | $30,650 | Implemented |
AM0553 # 05 Y:2008 | 05 | 2008 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $12,380 | $0 | Implemented |
AM0553 # 06 Y:2008 | 06 | 2008 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $4,970 | $500 | Implemented |
AM0553 # 08 Y:2008 | 08 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $460 | $325 | Implemented |
SD0400 # 05 Y:2007 | 05 | 2007 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $2,816 | $2,235 | Implemented |
UA0008 # 02 Y:2007 | 02 | 2007 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $11,848 | $0 | Implemented |
UA0008 # 03 Y:2007 | 03 | 2007 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $23,233 | $1,400 | Implemented |
UA0008 # 06 Y:2007 | 06 | 2007 | ADJUST BURNERS FOR EFFICIENT OPERATION | $6,248 | $200 | Implemented |
UA0008 # 07 Y:2007 | 07 | 2007 | ADJUST BURNERS FOR EFFICIENT OPERATION | $5,679 | $200 | Implemented |
LL0263 # 01 Y:2007 | 01 | 2007 | INSTALL SMALLER BOILER (INCREASE HIGH FIRE DUTY CYCLE) | $436,374 | $470,000 | Implemented |
LL0263 # 03 Y:2007 | 03 | 2007 | INSULATE BARE EQUIPMENT | $88,211 | $4,182 | Implemented |
LL0263 # 04 Y:2007 | 04 | 2007 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $73,876 | $28,200 | Implemented |
LL0263 # 06 Y:2007 | 06 | 2007 | USE PHOTOCELL CONTROLS | $6,235 | $990 | Implemented |
LL0263 # 07 Y:2007 | 07 | 2007 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $2,431 | $745 | Implemented |
IA0390 # 01 Y:2006 | 01 | 2006 | ADJUST BURNERS FOR EFFICIENT OPERATION | $53,488 | $1,000 | Implemented |
IA0390 # 04 Y:2006 | 04 | 2006 | REPAIR AND ELIMINATE STEAM LEAKS | $8,812 | $3,600 | Implemented |
IA0390 # 07 Y:2006 | 07 | 2006 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,305 | $896 | Implemented |
LM0111 # 02 Y:2006 | 02 | 2006 | INSULATE BARE EQUIPMENT | $2,109 | $3,000 | Implemented |
LM0111 # 03 Y:2006 | 03 | 2006 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $879 | $5,000 | Implemented |