Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

281

matching recommendations
Reset
SIC 2952 Asphalt Felts And Coatings
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
LL0263 # 06 Y:2007 06 2007 USE PHOTOCELL CONTROLS $6,235 $990 Implemented
LL0263 # 04 Y:2007 04 2007 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $73,876 $28,200 Implemented
LL0263 # 03 Y:2007 03 2007 INSULATE BARE EQUIPMENT $88,211 $4,182 Implemented
LL0263 # 01 Y:2007 01 2007 INSTALL SMALLER BOILER (INCREASE HIGH FIRE DUTY CYCLE) $436,374 $470,000 Implemented
LM0111 # 06 Y:2006 06 2006 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE $650,132 $0 Implemented
LM0111 # 03 Y:2006 03 2006 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $879 $5,000 Implemented
LM0111 # 02 Y:2006 02 2006 INSULATE BARE EQUIPMENT $2,109 $3,000 Implemented
OK0719 # 06 Y:2006 06 2006 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $221 $225 Implemented
OK0719 # 05 Y:2006 05 2006 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $282 $80 Implemented
OK0719 # 03 Y:2006 03 2006 USE OPTIMUM THICKNESS INSULATION $3,078 $1,637 Implemented
OK0719 # 02 Y:2006 02 2006 REPAIR AND ELIMINATE STEAM LEAKS $13,491 $550 Implemented
CO0580 # 04 Y:2006 04 2006 INCREASE AMOUNT OF CONDENSATE RETURNED $3,750 $12,850 Implemented
CO0580 # 05 Y:2006 05 2006 DIRECT WARMEST AIR TO COMBUSTION INTAKE $3,310 $980 Implemented
CO0580 # 07 Y:2006 07 2006 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $50 $20 Implemented
CO0580 # 09 Y:2006 09 2006 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $660 $1,830 Implemented
CO0580 # 11 Y:2006 11 2006 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $280 $500 Implemented
CO0580 # 02 Y:2006 02 2006 REPAIR AND ELIMINATE STEAM LEAKS $10,650 $500 Implemented
GT0803 # 01 Y:2005 01 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,764 $944 Implemented
GT0803 # 08 Y:2005 08 2005 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $779 $695 Implemented
GT0803 # 07 Y:2005 07 2005 USE PHOTOCELL CONTROLS $2,516 $570 Implemented
GT0803 # 04 Y:2005 04 2005 ADJUST BURNERS FOR EFFICIENT OPERATION $26,869 $3,000 Implemented
GT0803 # 03 Y:2005 03 2005 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $16,504 $7,500 Implemented
GT0803 # 02 Y:2005 02 2005 ADJUST BURNERS FOR EFFICIENT OPERATION $11,058 $1,000 Implemented
LE0204 # 03 Y:2005 03 2005 ESTABLISH EQUIPMENT MAINTENANCE SCHEDULE $4,345 $2,750 Implemented
LE0204 # 02 Y:2005 02 2005 INSULATE FEEDWATER TANK $18,286 $8,304 Implemented