Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
7,818
matching recommendationsSIC | 30 | Rubber And Miscellaneous Plastics Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
IA0304 # 12 Y:2002 | 12 | 2002 | INSULATE BARE EQUIPMENT | $85 | $180 | Implemented |
UD0657 # 01 Y:2002 | 01 | 2002 | DEVELOP STANDARD OPERATING PROCEDURES | $1,600,000 | $339,333 | Implemented |
UD0657 # 04 Y:2002 | 04 | 2002 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,470 | $0 | Implemented |
SF0245 # 03 Y:2002 | 03 | 2002 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $2,576 | $4,115 | Implemented |
SF0245 # 04 Y:2002 | 04 | 2002 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $8,585 | $20,725 | Implemented |
SF0245 # 06 Y:2002 | 06 | 2002 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $2,738 | $6,972 | Implemented |
SF0245 # 07 Y:2002 | 07 | 2002 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $5,193 | $0 | Implemented |
MA0523 # 02 Y:2002 | 02 | 2002 | OPTIMIZE PLANT POWER FACTOR | $6,907 | $11,770 | Implemented |
MA0523 # 03 Y:2002 | 03 | 2002 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $2,108 | $0 | Implemented |
MA0523 # 04 Y:2002 | 04 | 2002 | PAY BILLS ON TIME TO AVOID LATE FEES | $1,510 | $0 | Implemented |
MA0523 # 06 Y:2002 | 06 | 2002 | INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS | $467 | $250 | Implemented |
MA0523 # 07 Y:2002 | 07 | 2002 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $359 | $230 | Implemented |
AM0421 # 01 Y:2002 | 01 | 2002 | INSTALL EQUIPMENT TO MOVE PRODUCT | $9,360 | $7,880 | Implemented |
AM0421 # 02 Y:2002 | 02 | 2002 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $7,040 | $0 | Implemented |
AM0421 # 03 Y:2002 | 03 | 2002 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,230 | $500 | Implemented |
AM0421 # 05 Y:2002 | 05 | 2002 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $610 | $2,800 | Implemented |
AM0421 # 07 Y:2002 | 07 | 2002 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $395 | $180 | Implemented |
AM0421 # 09 Y:2002 | 09 | 2002 | USE PHOTOCELL CONTROLS | $110 | $20 | Implemented |
LE0146 # 02 Y:2002 | 02 | 2002 | INSTALL OCCUPANCY SENSORS | $1,559 | $3,000 | Implemented |
LE0146 # 03 Y:2002 | 03 | 2002 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $10,443 | $0 | Implemented |
UD0653 # 01 Y:2002 | 01 | 2002 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $1,356,000 | $500,000 | Implemented |
UD0653 # 02 Y:2002 | 02 | 2002 | DEVELOP STANDARD OPERATING PROCEDURES | $222,000 | $0 | Implemented |
UD0653 # 04 Y:2002 | 04 | 2002 | INSULATE BARE EQUIPMENT | $6,181 | $733 | Implemented |
UD0653 # 06 Y:2002 | 06 | 2002 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,378 | $5,112 | Implemented |
UD0653 # 08 Y:2002 | 08 | 2002 | REDUCE FLUID FLOW RATES | $1,381 | $0 | Implemented |