Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
7,818
matching recommendationsSIC | 30 | Rubber And Miscellaneous Plastics Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
TN0640 # 06 Y:1998 | 06 | 1998 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $85 | $50 | Implemented |
AR0142 # 01 Y:1998 | 01 | 1998 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $311 | $655 | Implemented |
AR0142 # 02 Y:1998 | 02 | 1998 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $866 | $0 | Implemented |
AR0142 # 03 Y:1998 | 03 | 1998 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $272 | $186 | Implemented |
AR0142 # 04 Y:1998 | 04 | 1998 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,472 | $50 | Implemented |
AR0142 # 05 Y:1998 | 05 | 1998 | INSTALL / REPAIR INSULATION ON STEAM LINES | $757 | $652 | Implemented |
WI0328 # 01 Y:1998 | 01 | 1998 | CLEAR AND RENT EXISTING SPACE | $18,977 | $0 | Implemented |
WI0328 # 08 Y:1998 | 08 | 1998 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $380 | $840 | Implemented |
OK0551 # 01 Y:1998 | 01 | 1998 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $898 | $80,000 | Implemented |
OK0551 # 04 Y:1998 | 04 | 1998 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $4,304 | $0 | Implemented |
OK0551 # 05 Y:1998 | 05 | 1998 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $2,522 | $0 | Implemented |
SD0206 # 02 Y:1998 | 02 | 1998 | SHIFT FROM DAYTIME TO NIGHTTIME OPERATION | $5,837 | $0 | Implemented |
SD0206 # 03 Y:1998 | 03 | 1998 | USE OPTIMUM THICKNESS INSULATION | $2,817 | $1,076 | Implemented |
SD0206 # 04 Y:1998 | 04 | 1998 | INSTALL SPECTRAL REFLECTORS / DELAMP | $519 | $1,260 | Implemented |
SD0206 # 05 Y:1998 | 05 | 1998 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,374 | $0 | Implemented |
SD0206 # 06 Y:1998 | 06 | 1998 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $3,218 | $8,500 | Implemented |
SD0206 # 07 Y:1998 | 07 | 1998 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $6,426 | $1,275 | Implemented |
SD0206 # 08 Y:1998 | 08 | 1998 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $157,414 | $12,000 | Implemented |
SD0203 # 08 Y:1998 | 08 | 1998 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $600 | $0 | Implemented |
SD0203 # 09 Y:1998 | 09 | 1998 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $4,400 | $8,500 | Implemented |
KU0496 # 03 Y:1998 | 03 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,850 | $7,290 | Implemented |
KU0496 # 04 Y:1998 | 04 | 1998 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,770 | $600 | Implemented |
KU0496 # 05 Y:1998 | 05 | 1998 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,760 | $1,000 | Implemented |
KU0496 # 06 Y:1998 | 06 | 1998 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,350 | $2,900 | Implemented |
KU0496 # 07 Y:1998 | 07 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $620 | $720 | Implemented |