Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
4,537
matching recommendationsSIC | 33 | Primary Metal Industries |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LL0288 # 01 Y:2008 | 01 | 2008 | REPAIR AND ELIMINATE STEAM LEAKS | $36,904 | $5,110 | Implemented |
LL0288 # 03 Y:2008 | 03 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,639 | $840 | Implemented |
LL0288 # 04 Y:2008 | 04 | 2008 | INSULATE BARE EQUIPMENT | $3,002 | $1,635 | Implemented |
BD0335 # 03 Y:2008 | 03 | 2008 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $109,544 | $73,511 | Implemented |
BD0335 # 04 Y:2008 | 04 | 2008 | USE SYNTHETIC LUBRICANT | $2,411 | $501 | Implemented |
BD0335 # 06 Y:2008 | 06 | 2008 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,080 | $2 | Implemented |
NC0371 # 02 Y:2008 | 02 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $444 | $100 | Implemented |
NC0371 # 03 Y:2008 | 03 | 2008 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $15,277 | $17,280 | Implemented |
NC0371 # 09 Y:2008 | 09 | 2008 | INSULATE BARE EQUIPMENT | $288 | $485 | Implemented |
UD0773 # 01 Y:2008 | 01 | 2008 | UPGRADE CONTROLS ON COMPRESSORS | $79,805 | $20,000 | Implemented |
UD0773 # 03 Y:2008 | 03 | 2008 | ENHANCE SENSITIVITY OF TEMPERATURE CONTROL AND CUTOFF | $22,200 | $15,000 | Implemented |
UD0773 # 07 Y:2008 | 07 | 2008 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $9,990 | $0 | Implemented |
UA0013 # 01 Y:2007 | 01 | 2007 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $19,423 | $700 | Implemented |
UA0013 # 03 Y:2007 | 03 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $11,315 | $47,838 | Implemented |
UA0013 # 04 Y:2007 | 04 | 2007 | INSTALL OCCUPANCY SENSORS | $17,411 | $13,088 | Implemented |
UA0013 # 07 Y:2007 | 07 | 2007 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $4,856 | $0 | Implemented |
SF0349 # 01 Y:2007 | 01 | 2007 | REPAIR AND ELIMINATE STEAM LEAKS | $6,853 | $0 | Implemented |
SF0349 # 03 Y:2007 | 03 | 2007 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,755 | $0 | Implemented |
SF0349 # 05 Y:2007 | 05 | 2007 | INSTALL OCCUPANCY SENSORS | $3,490 | $1,992 | Implemented |
SF0349 # 06 Y:2007 | 06 | 2007 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $725 | $757 | Implemented |
SF0349 # 10 Y:2007 | 10 | 2007 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $3,554 | $4,281 | Implemented |
SF0349 # 12 Y:2007 | 12 | 2007 | USE PHOTOCELL CONTROLS | $3,302 | $9,569 | Implemented |
BD0334 # 01 Y:2007 | 01 | 2007 | USE RADIANT HEATER FOR SPOT HEATING | $242,313 | $111,001 | Implemented |
BD0334 # 04 Y:2007 | 04 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,532 | $3,690 | Implemented |
BD0334 # 05 Y:2007 | 05 | 2007 | INSTALL OCCUPANCY SENSORS | $3,999 | $1,576 | Implemented |