Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
130
matching recommendationsSIC | 3432 | Plumbing Fixture Fittings And Trim |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AM0357 # 09 Y:1999 | 09 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $150 | $150 | Implemented |
SD0233 # 01 Y:1999 | 01 | 1999 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $331 | $725 | Implemented |
SD0233 # 02 Y:1999 | 02 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,292 | $360 | Implemented |
SD0233 # 03 Y:1999 | 03 | 1999 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $940 | $584 | Implemented |
SD0233 # 04 Y:1999 | 04 | 1999 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,392 | $1,394 | Implemented |
SD0233 # 05 Y:1999 | 05 | 1999 | MAINTAIN MACHINES TO REDUCE LEAKS | $6,160 | $0 | Implemented |
BD0126 # 02 Y:1999 | 02 | 1999 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $25,009 | $31,450 | Implemented |
BD0126 # 03 Y:1999 | 03 | 1999 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $7,739 | $3,302 | Implemented |
BD0126 # 05 Y:1999 | 05 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,658 | $1,125 | Implemented |
BD0126 # 06 Y:1999 | 06 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,785 | $2,365 | Implemented |
BD0126 # 07 Y:1999 | 07 | 1999 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $16,941 | $14,000 | Implemented |
BD0126 # 08 Y:1999 | 08 | 1999 | USE EVAPORATION TO CONCENTRATE MATERIAL | $8,527 | $5,500 | Implemented |
BD0126 # 09 Y:1999 | 09 | 1999 | MODIFY PROCESS TO REDUCE MATERIAL USE/COST | $6,005 | $1,500 | Implemented |
NC0156 # 03 Y:1999 | 03 | 1999 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $461,046 | $1,000,000 | Implemented |
NC0156 # 04 Y:1999 | 04 | 1999 | RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING | $65,000 | $80,000 | Implemented |
AR0137 # 01 Y:1998 | 01 | 1998 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,861 | $190 | Implemented |
AR0137 # 02 Y:1998 | 02 | 1998 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $3,790 | $628 | Implemented |
AR0137 # 03 Y:1998 | 03 | 1998 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,133 | $2,052 | Implemented |
AR0137 # 04 Y:1998 | 04 | 1998 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,002 | $0 | Implemented |
AR0137 # 05 Y:1998 | 05 | 1998 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $4,811 | $215 | Implemented |
AR0137 # 06 Y:1998 | 06 | 1998 | RECOVER AND REUSE COOLING WATER | $4,245 | $800 | Implemented |
AR0137 # 08 Y:1998 | 08 | 1998 | DISTILL CONTAMINATED SOLVENTS FOR REUSE | $9,565 | $4,500 | Implemented |
AR0137 # 09 Y:1998 | 09 | 1998 | MOVE PRODUCT USING MECHANICAL MEANS | $65,025 | $14,555 | Implemented |
CO0370 # 03 Y:1996 | 03 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $319 | $623 | Implemented |
CO0370 # 04 Y:1996 | 04 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $156 | $217 | Implemented |