Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
116
matching recommendationsSIC | 3432 | Plumbing Fixture Fittings And Trim |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0156 # 04 Y:1999 | 04 | 1999 | RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING | $65,000 | $80,000 | Implemented |
AR0137 # 01 Y:1998 | 01 | 1998 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,861 | $190 | Implemented |
AR0137 # 02 Y:1998 | 02 | 1998 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $3,790 | $628 | Implemented |
AR0137 # 03 Y:1998 | 03 | 1998 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,133 | $2,052 | Implemented |
AR0137 # 04 Y:1998 | 04 | 1998 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,002 | $0 | Implemented |
AR0137 # 05 Y:1998 | 05 | 1998 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $4,811 | $215 | Implemented |
AR0137 # 06 Y:1998 | 06 | 1998 | RECOVER AND REUSE COOLING WATER | $4,245 | $800 | Implemented |
AR0137 # 08 Y:1998 | 08 | 1998 | DISTILL CONTAMINATED SOLVENTS FOR REUSE | $9,565 | $4,500 | Implemented |
AR0137 # 09 Y:1998 | 09 | 1998 | MOVE PRODUCT USING MECHANICAL MEANS | $65,025 | $14,555 | Implemented |
CO0370 # 03 Y:1996 | 03 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $319 | $623 | Implemented |
CO0370 # 04 Y:1996 | 04 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $156 | $217 | Implemented |
CO0370 # 05 Y:1996 | 05 | 1996 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $500 | $60 | Implemented |
TN0504 # 01 Y:1993 | 01 | 1993 | INSTALL TIMERS AND/OR THERMOSTATS | $9,438 | $3,000 | Implemented |
TN0504 # 02 Y:1993 | 02 | 1993 | INSULATE BARE EQUIPMENT | $8,307 | $1,125 | Implemented |
TN0504 # 04 Y:1993 | 04 | 1993 | REPAIR AND ELIMINATE STEAM LEAKS | $2,208 | $1,350 | Implemented |
TN0504 # 05 Y:1993 | 05 | 1993 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $2,202 | $1,500 | Implemented |
TN0504 # 06 Y:1993 | 06 | 1993 | INSULATE BARE EQUIPMENT | $7,362 | $770 | Implemented |
TN0504 # 09 Y:1993 | 09 | 1993 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,227 | $1,416 | Implemented |
TN0504 # 10 Y:1993 | 10 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,383 | $1,856 | Implemented |
TN0504 # 11 Y:1993 | 11 | 1993 | INSULATE BARE EQUIPMENT | $318 | $375 | Implemented |
TN0505 # 01 Y:1993 | 01 | 1993 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $10,734 | $4,088 | Implemented |
TN0505 # 02 Y:1993 | 02 | 1993 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $10,127 | $730 | Implemented |
TN0505 # 04 Y:1993 | 04 | 1993 | INSTALL SPECTRAL REFLECTORS / DELAMP | $6,669 | $15,914 | Implemented |
TN0505 # 07 Y:1993 | 07 | 1993 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $525 | $1,380 | Implemented |
TN0505 # 08 Y:1993 | 08 | 1993 | OPTIMIZE PLANT POWER FACTOR | $6,244 | $15,800 | Implemented |