Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,546
matching recommendationsSIC | 344 | Fabricated Structural Metal Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SF0473 # 06 Y:2015 | 06 | 2015 | UPGRADE CONTROLS ON COMPRESSORS | $10,962 | $10,585 | Implemented |
SF0473 # 07 Y:2015 | 07 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $24,885 | $76,232 | Implemented |
SF0473 # 08 Y:2015 | 08 | 2015 | USE SOLAR HEAT TO MAKE ELECTRICTY | $121,903 | $1,110,964 | Implemented |
SF0473 # 09 Y:2015 | 09 | 2015 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $677 | $0 | Implemented |
UK1507 # 02 Y:2015 | 02 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $23,894 | $18,750 | Implemented |
UK1507 # 05 Y:2015 | 05 | 2015 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $20,784 | $18,960 | Implemented |
UK1507 # 07 Y:2015 | 07 | 2015 | UPGRADE CONTROLS ON COMPRESSORS | $6,513 | $7,500 | Implemented |
UK1507 # 09 Y:2015 | 09 | 2015 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $387 | $0 | Implemented |
UK1507 # 13 Y:2015 | 13 | 2015 | TURN OFF EQUIPMENT WHEN NOT IN USE | $660 | $0 | Implemented |
MZ0186 # 01 Y:2015 | 01 | 2015 | INSTALL OCCUPANCY SENSORS | $5,513 | $5,100 | Implemented |
MZ0186 # 03 Y:2015 | 03 | 2015 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,104 | $1,160 | Implemented |
MZ0186 # 04 Y:2015 | 04 | 2015 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $83 | $0 | Implemented |
TT0154 # 05 Y:2015 | 05 | 2015 | APPLY FOR INVESTMENT INCENTIVES | $5,176 | $40 | Implemented |
AM0680 # 01 Y:2015 | 01 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $17,460 | $23,910 | Implemented |
AM0680 # 02 Y:2015 | 02 | 2015 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,170 | $500 | Implemented |
AM0680 # 03 Y:2015 | 03 | 2015 | OPTIMIZE PLANT POWER FACTOR | $2,800 | $5,010 | Implemented |
AM0680 # 04 Y:2015 | 04 | 2015 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,510 | $2 | Implemented |
AM0680 # 05 Y:2015 | 05 | 2015 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $1,460 | $500 | Implemented |
AM0680 # 06 Y:2015 | 06 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $425 | $165 | Implemented |
AM0680 # 07 Y:2015 | 07 | 2015 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $370 | $0 | Implemented |
AM0680 # 08 Y:2015 | 08 | 2015 | USE SYNTHETIC LUBRICANT | $355 | $0 | Implemented |
AM0679 # 01 Y:2015 | 01 | 2015 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $16,000 | $4,040 | Implemented |
AM0679 # 02 Y:2015 | 02 | 2015 | OPTIMIZE PLANT POWER FACTOR | $5,340 | $6,060 | Implemented |
AM0679 # 04 Y:2015 | 04 | 2015 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $1,350 | $0 | Implemented |
WM0061 # 04 Y:2015 | 04 | 2015 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $7,688 | $5,526 | Implemented |