Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
460
matching recommendationsSIC | 3469 | Metal Stampings, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OR0347 # 04 Y:1999 | 04 | 1999 | OPTIMIZE PRODUCTION LOT SIZES AND INVENTORIES | $327,800 | $87,400 | Implemented |
DS0144 # 01 Y:1999 | 01 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,077 | $438 | Implemented |
DS0144 # 02 Y:1999 | 02 | 1999 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $567 | $259 | Implemented |
DS0144 # 04 Y:1999 | 04 | 1999 | TURN OFF EQUIPMENT WHEN NOT IN USE | $1,642 | $725 | Implemented |
DS0144 # 06 Y:1999 | 06 | 1999 | CONSIDER USE / PURCHASE OF BULK MATERIALS WHERE POSSIBLE | $2,225 | $1,350 | Implemented |
DS0144 # 07 Y:1999 | 07 | 1999 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $286 | $0 | Implemented |
UL0224 # 01 Y:1999 | 01 | 1999 | INSTALL TIMERS AND/OR THERMOSTATS | $1,406 | $1,200 | Implemented |
UL0224 # 02 Y:1999 | 02 | 1999 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $17,225 | $30,000 | Implemented |
IA0221 # 04 Y:1999 | 04 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $563 | $245 | Implemented |
IA0221 # 06 Y:1999 | 06 | 1999 | PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER | $25,571 | $2,950 | Implemented |
IA0221 # 08 Y:1999 | 08 | 1999 | RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE HANDLING COSTS | $20,642 | $11,793 | Implemented |
HO0204 # 01 Y:1999 | 01 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $10,583 | $16,842 | Implemented |
HO0204 # 02 Y:1999 | 02 | 1999 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $901 | $0 | Implemented |
HO0204 # 06 Y:1999 | 06 | 1999 | INSULATE FEEDWATER TANK | $526 | $438 | Implemented |
HO0204 # 07 Y:1999 | 07 | 1999 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $3,911 | $2,450 | Implemented |
HO0204 # 10 Y:1999 | 10 | 1999 | MAINTAIN/ENLARGE A STOCK OF SPARE PARTS | $1,125 | $318 | Implemented |
HO0204 # 13 Y:1999 | 13 | 1999 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $2,250 | $120 | Implemented |
UD0569 # 02 Y:1999 | 02 | 1999 | INCREASE USE OF AUTOMATION | $65,250 | $0 | Implemented |
UD0569 # 05 Y:1999 | 05 | 1999 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $6,848 | $632 | Implemented |
AS0231 # 01 Y:1998 | 01 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $11,912 | $23,975 | Implemented |
AS0231 # 04 Y:1998 | 04 | 1998 | INSTALL TIMERS AND/OR THERMOSTATS | $613 | $1,425 | Implemented |
AS0231 # 07 Y:1998 | 07 | 1998 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $616 | $60 | Implemented |
AS0231 # 09 Y:1998 | 09 | 1998 | RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE HANDLING COSTS | $12,854 | $450 | Implemented |
WV0140 # 02 Y:1998 | 02 | 1998 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $6,131 | $10,800 | Implemented |
WV0140 # 04 Y:1998 | 04 | 1998 | USE SYNTHETIC LUBRICANT | $498 | $342 | Implemented |