Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
32
matching recommendationsSIC | 3498 | Fabricated Pipe And Fittings |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0686 # 07 Y:2004 | 07 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $537 | $2,550 | Implemented |
OK0686 # 06 Y:2004 | 06 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,153 | $36,618 | Implemented |
OK0686 # 04 Y:2004 | 04 | 2004 | INSTALL SET-BACK TIMERS | $1,577 | $1,320 | Implemented |
OK0686 # 03 Y:2004 | 03 | 2004 | INSTALL OCCUPANCY SENSORS | $3,350 | $1,136 | Implemented |
OK0686 # 02 Y:2004 | 02 | 2004 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $1,472 | $262 | Implemented |
OK0610 # 01 Y:2001 | 01 | 2001 | INSTALL SET-BACK TIMERS | $14,000 | $1,670 | Implemented |
OK0583 # 07 Y:1999 | 07 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $775 | $500 | Implemented |
OK0583 # 06 Y:1999 | 06 | 1999 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,107 | $1,500 | Implemented |
OK0583 # 03 Y:1999 | 03 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,239 | $25,525 | Implemented |
OK0522 # 08 Y:1997 | 08 | 1997 | ELIMINATE SHIFT | $10,400 | $200 | Implemented |
OK0522 # 04 Y:1997 | 04 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $-70 | $386 | Implemented |
OK0522 # 03 Y:1997 | 03 | 1997 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $103 | $200 | Implemented |
OK0522 # 02 Y:1997 | 02 | 1997 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $1,918 | $3,500 | Implemented |
OK0522 # 01 Y:1997 | 01 | 1997 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $844 | $2,845 | Implemented |
OK0509 # 05 Y:1996 | 05 | 1996 | TURN OFF EQUIPMENT WHEN NOT IN USE | $470 | $460 | Implemented |
OK0509 # 06 Y:1996 | 06 | 1996 | INSTALL TIMERS AND/OR THERMOSTATS | $538 | $248 | Implemented |
OK0509 # 04 Y:1996 | 04 | 1996 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,419 | $855 | Implemented |
OK0509 # 02 Y:1996 | 02 | 1996 | RE-SIZE CHARGING OPENINGS OR ADD A MOVABLE DOOR ON EQUIPMENT | $14,966 | $18,000 | Implemented |
OK0509 # 01 Y:1996 | 01 | 1996 | ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS | $1,243 | $0 | Implemented |
OK0265 # 07 Y:1988 | 07 | 1988 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $53,297 | $0 | Implemented |
OK0265 # 04 Y:1988 | 04 | 1988 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,423 | $15 | Implemented |
OK0265 # 03 Y:1988 | 03 | 1988 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,364 | $901 | Implemented |
OK0265 # 02 Y:1988 | 02 | 1988 | IMPROVE LUBRICATION PRACTICES | $2,711 | $0 | Implemented |
OK0265 # 01 Y:1988 | 01 | 1988 | INSTALL TIMERS AND/OR THERMOSTATS | $204 | $450 | Implemented |
OK0249 # 04 Y:1988 | 04 | 1988 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $209 | $490 | Implemented |