Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

125

matching recommendations
Reset
SIC 3541 Machine Tools, Metal Cutting Types
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
WI0387 # 09 Y:2001 09 2001 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $630 $640 Implemented
WI0387 # 10 Y:2001 10 2001 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $387 $90 Implemented
OK0594 # 01 Y:2000 01 2000 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $9,935 $800 Implemented
OK0594 # 02 Y:2000 02 2000 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $8,177 $13,490 Implemented
OK0594 # 03 Y:2000 03 2000 INSTALL SKYLIGHTS $3,419 $2,000 Implemented
OK0594 # 05 Y:2000 05 2000 INSTALL OCCUPANCY SENSORS $3,339 $860 Implemented
ME0281 # 03 Y:2000 03 2000 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,461 $50 Implemented
ME0281 # 04 Y:2000 04 2000 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $2,277 $300 Implemented
ME0281 # 05 Y:2000 05 2000 UTILIZE A CENTRAL COOLANT SYSTEM FOR CLEANING AND REUSE OF METAL WORKING FLUID $80,452 $92,000 Implemented
UD0561 # 03 Y:1999 03 1999 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $5,566 $8,140 Implemented
UD0561 # 04 Y:1999 04 1999 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,418 $14,216 Implemented
OD0093 # 01 Y:1997 01 1997 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,668 $11,164 Implemented
OD0093 # 02 Y:1997 02 1997 UPGRADE CONTROLS ON COMPRESSORS $322 $560 Implemented
NV0070 # 01 Y:1996 01 1996 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $6,386 $20 Implemented
NV0070 # 02 Y:1996 02 1996 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $743 $200 Implemented
NV0070 # 03 Y:1996 03 1996 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $413 $0 Implemented
NV0070 # 04 Y:1996 04 1996 INSTALL OCCUPANCY SENSORS $968 $282 Implemented
NV0070 # 05 Y:1996 05 1996 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $1,846 $920 Implemented
NV0070 # 06 Y:1996 06 1996 USE OPTIMUM SIZE AND CAPACITY EQUIPMENT $3,238 $180 Implemented
SD0157 # 01 Y:1996 01 1996 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $2,138 $1,520 Implemented
SD0157 # 03 Y:1996 03 1996 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $970 $950 Implemented
SD0157 # 04 Y:1996 04 1996 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED $1,120 $300 Implemented
SD0157 # 05 Y:1996 05 1996 TURN OFF EQUIPMENT WHEN NOT IN USE $503 $300 Implemented
SD0157 # 06 Y:1996 06 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,289 $1,968 Implemented
SD0157 # 08 Y:1996 08 1996 INSTALL OCCUPANCY SENSORS $1,743 $1,255 Implemented