Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
114
matching recommendationsSIC | 3566 | Speed Changers, Drives, And Gears |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0816 # 11 Y:2011 | 11 | 2011 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,760 | $1,338 | Implemented |
SU0309 # 01 Y:2011 | 01 | 2011 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $201 | $0 | Implemented |
SU0309 # 05 Y:2011 | 05 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $68 | $228 | Implemented |
SU0309 # 08 Y:2011 | 08 | 2011 | UPGRADE OBSOLETE EQUIPMENT | $1,442 | $16,500 | Implemented |
SU0309 # 07 Y:2011 | 07 | 2011 | UPGRADE OBSOLETE EQUIPMENT | $116 | $1,258 | Implemented |
SU0309 # 02 Y:2011 | 02 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $255 | $147 | Implemented |
UW0004 # 02 Y:2007 | 02 | 2007 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $7,182 | $25,800 | Implemented |
UW0004 # 01 Y:2007 | 01 | 2007 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $13,962 | $8,762 | Implemented |
LM0070 # 09 Y:2004 | 09 | 2004 | MODIFY WORKLOAD | $855,000 | $50,000 | Implemented |
LM0070 # 01 Y:2004 | 01 | 2004 | DISCONNECT BALLASTS | $4,442 | $0 | Implemented |
LM0070 # 02 Y:2004 | 02 | 2004 | INSTALL OCCUPANCY SENSORS | $1,970 | $110 | Implemented |
LM0070 # 04 Y:2004 | 04 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,020 | $1,000 | Implemented |
LM0070 # 05 Y:2004 | 05 | 2004 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $486 | $0 | Implemented |
LM0070 # 07 Y:2004 | 07 | 2004 | MODIFY STARTUP/SHUTDOWN TIMES | $13,976 | $1,000 | Implemented |
LM0070 # 08 Y:2004 | 08 | 2004 | ELIMINATE SHIFT | $15,698 | $1,000 | Implemented |
NC0271 # 01 Y:2003 | 01 | 2003 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $5,523 | $50 | Implemented |
NC0271 # 05 Y:2003 | 05 | 2003 | DEVELOP A REPAIR/REPLACE POLICY | $204 | $150 | Implemented |
NC0271 # 06 Y:2003 | 06 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $796 | $100 | Implemented |
IC0070 # 07 Y:2003 | 07 | 2003 | TURN OFF EQUIPMENT WHEN NOT IN USE | $58,133 | $0 | Implemented |
IC0070 # 06 Y:2003 | 06 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $56,367 | $4,200 | Implemented |
IC0067 # 06 Y:2003 | 06 | 2003 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $1,376 | $0 | Implemented |
IC0067 # 02 Y:2003 | 02 | 2003 | TURN OFF EQUIPMENT WHEN NOT IN USE | $3,485 | $0 | Implemented |
IC0067 # 01 Y:2003 | 01 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $8,779 | $2,600 | Implemented |
MS0215 # 01 Y:2002 | 01 | 2002 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $2,023 | $50 | Implemented |
MS0215 # 04 Y:2002 | 04 | 2002 | INSTALL TIMERS AND/OR THERMOSTATS | $500 | $708 | Implemented |