Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
80
matching recommendationsSIC | 3694 | Engine Electrical Equipment |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
IA0508 # 03 Y:2013 | 03 | 2013 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $2,845 | $1,000 | Implemented |
IA0508 # 02 Y:2013 | 02 | 2013 | REPAIR OR REPLACE STEAM TRAPS | $14,349 | $3,750 | Implemented |
IA0508 # 09 Y:2013 | 09 | 2013 | INSTALL / REPAIR INSULATION ON STEAM LINES | $3,758 | $976 | Implemented |
WV0474 # 03 Y:2013 | 03 | 2013 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $5,698 | $1,000 | Implemented |
WV0474 # 10 Y:2013 | 10 | 2013 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $407 | $500 | Implemented |
WV0474 # 06 Y:2013 | 06 | 2013 | DEVELOP A REPAIR/REPLACE POLICY | $1,715 | $392 | Implemented |
WV0474 # 05 Y:2013 | 05 | 2013 | CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE | $2,920 | $72 | Implemented |
WV0474 # 07 Y:2013 | 07 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,586 | $324 | Implemented |
WV0474 # 01 Y:2013 | 01 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $12,986 | $15,864 | Implemented |
UF0430 # 02 Y:2010 | 02 | 2010 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $1,044 | $0 | Implemented |
UF0430 # 07 Y:2010 | 07 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $7,016 | $404 | Implemented |
UF0430 # 04 Y:2010 | 04 | 2010 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $2,547 | $0 | Implemented |
UF0430 # 08 Y:2010 | 08 | 2010 | AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM | $6,842 | $0 | Implemented |
UF0430 # 01 Y:2010 | 01 | 2010 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $28,959 | $5,655 | Implemented |
OK0639 # 01 Y:2002 | 01 | 2002 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $5,500 | $0 | Implemented |
OK0639 # 03 Y:2002 | 03 | 2002 | INSTALL OCCUPANCY SENSORS | $258 | $717 | Implemented |
OK0639 # 05 Y:2002 | 05 | 2002 | INSTALL SET-BACK TIMERS | $6,583 | $160 | Implemented |
OK0639 # 06 Y:2002 | 06 | 2002 | CHANGE ZONE REHEAT COILS TO VARIABLE AIR VOLUME BOXES | $6,380 | $14,226 | Implemented |
AM0284 # 02 Y:1996 | 02 | 1996 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $13,620 | $15,360 | Implemented |
AM0284 # 04 Y:1996 | 04 | 1996 | CONVERT TO AQUEOUS CLEANING SYSTEM | $6,652 | $6,168 | Implemented |
AM0284 # 03 Y:1996 | 03 | 1996 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $7,130 | $600 | Implemented |
AM0284 # 01 Y:1996 | 01 | 1996 | UPGRADE OBSOLETE EQUIPMENT | $899,930 | $2,500,000 | Implemented |
ND0243 # 11 Y:1996 | 11 | 1996 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $7,180 | $800 | Implemented |
ND0243 # 09 Y:1996 | 09 | 1996 | OPTIMIZE PLANT POWER FACTOR | $265 | $192 | Implemented |
ND0243 # 06 Y:1996 | 06 | 1996 | REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED | $41 | $0 | Implemented |