Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
29
matching recommendationsSIC | 382 | Measuring And Controlling Devices |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MA0446 # 03 Y:1999 | 03 | 1999 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $14,463 | $20,800 | Implemented |
MA0446 # 04 Y:1999 | 04 | 1999 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $9,237 | $3,575 | Implemented |
MA0446 # 06 Y:1999 | 06 | 1999 | VENTILATION SYSTEM TO SHUT OFF WHEN ROOM IS NOT IN USE | $2,849 | $0 | Implemented |
MA0446 # 07 Y:1999 | 07 | 1999 | AIR CONDITION ONLY SPACE NECESSARY | $1,137 | $2,670 | Implemented |
MA0446 # 10 Y:1999 | 10 | 1999 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $638 | $300 | Implemented |
WI0359 # 05 Y:1999 | 05 | 1999 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,815 | $100 | Implemented |
WI0359 # 06 Y:1999 | 06 | 1999 | INSTALL SPECTRAL REFLECTORS / DELAMP | $1,781 | $0 | Implemented |
WI0359 # 09 Y:1999 | 09 | 1999 | REDUCE VENTILATION AIR | $648 | $500 | Implemented |
WI0359 # 10 Y:1999 | 10 | 1999 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $278 | $0 | Implemented |
SD0228 # 05 Y:1999 | 05 | 1999 | $793 | $0 | Implemented | |
SD0228 # 01 Y:1999 | 01 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $14,410 | $6,484 | Implemented |
UD0568 # 03 Y:1999 | 03 | 1999 | CHANGE ZONE REHEAT COILS TO VARIABLE AIR VOLUME BOXES | $5,171 | $4,000 | Implemented |
MA0434 # 03 Y:1999 | 03 | 1999 | INSTALL OCCUPANCY SENSORS | $230 | $130 | Implemented |
MA0434 # 04 Y:1999 | 04 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $71 | $50 | Implemented |
DS0131 # 01 Y:1999 | 01 | 1999 | INSTALL OCCUPANCY SENSORS | $95 | $216 | Implemented |
DS0131 # 02 Y:1999 | 02 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $474 | $81 | Implemented |
ME0260 # 04 Y:1999 | 04 | 1999 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $585 | $171 | Implemented |
SF0159 # 05 Y:1999 | 05 | 1999 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $977 | $1,439 | Implemented |
SF0159 # 04 Y:1999 | 04 | 1999 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,977 | $0 | Implemented |
SF0159 # 02 Y:1999 | 02 | 1999 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $4,207 | $1,400 | Implemented |
SF0159 # 06 Y:1999 | 06 | 1999 | OPTIMIZE PLANT POWER FACTOR | $3,156 | $5,517 | Implemented |
SF0159 # 01 Y:1999 | 01 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,720 | $0 | Implemented |
SF0159 # 07 Y:1999 | 07 | 1999 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $1,452 | $2,550 | Implemented |
SF0159 # 08 Y:1999 | 08 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,589 | $21,750 | Implemented |
SF0159 # 09 Y:1999 | 09 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,339 | $1,339 | Implemented |