IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

20,411

matching recommendations
Reset
ARC 2.2 Thermal Systems
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
AM0141 # 02 Y:1992 02 1992 INSULATE BARE EQUIPMENT $7,250 $1,670 Implemented
AM0141 # 08 Y:1992 08 1992 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $1,820 $3,500 Not Implemented
AM0141 # 09 Y:1992 09 1992 RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR $730 $4,800 Implemented
AM0142 # 01 Y:1992 01 1992 INSTALL / REPAIR INSULATION ON STEAM LINES $2,900 $4,520 Implemented
AM0142 # 04 Y:1992 04 1992 REPAIR AND ELIMINATE STEAM LEAKS $1,390 $800 Implemented
SD0011 # 02 Y:1992 02 1992 INSULATE BARE EQUIPMENT $138 $190 Not Implemented
SD0012 # 01 Y:1992 01 1992 INSULATE BARE EQUIPMENT $6,376 $287 Implemented
SD0012 # 02 Y:1992 02 1992 RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR $1,350 $150 Not Implemented
SD0013 # 02 Y:1992 02 1992 RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR $5,150 $367 Not Implemented
SD0013 # 03 Y:1992 03 1992 RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR $2,029 $400 Not Implemented
WI0138 # 06 Y:1992 06 1992 REPAIR AND ELIMINATE STEAM LEAKS $247 $200 Implemented
WI0138 # 07 Y:1992 07 1992 INSULATE BARE EQUIPMENT $331 $168 Implemented
TN0451 # 02 Y:1992 02 1992 RECOVER WASTE HEAT FROM EQUIPMENT $1,656 $1,330 Not Implemented
TN0452 # 05 Y:1992 05 1992 INSULATE BARE EQUIPMENT $490 $182 Not Implemented
UD0361 # 04 Y:1992 04 1992 USE COOLING AIR WHICH COOLS HOT WORK PIECES FOR SPACE HEATING $4,283 $7,500 Not Implemented
UD0361 # 05 Y:1992 05 1992 RECOVER WASTE HEAT FROM EQUIPMENT $639 $2,500 Implemented
MO0049 # 04 Y:1992 04 1992 REPAIR AND ELIMINATE STEAM LEAKS $321 $100 Implemented
MA0232 # 01 Y:1992 01 1992 RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR $31,842 $90,600 Not Implemented
MA0232 # 03 Y:1992 03 1992 REPAIR OR REPLACE STEAM TRAPS $2,293 $2 Implemented
MA0232 # 05 Y:1992 05 1992 INCREASE AMOUNT OF CONDENSATE RETURNED $884 $150 Implemented
MA0233 # 01 Y:1992 01 1992 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $28,770 $2,000 Implemented
MA0233 # 02 Y:1992 02 1992 CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE $4,263 $0 Not Implemented
MA0233 # 03 Y:1992 03 1992 INSULATE BARE EQUIPMENT $10,672 $12,412 Implemented
MA0233 # 04 Y:1992 04 1992 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $7,341 $14,210 Implemented
MA0233 # 06 Y:1992 06 1992 SUBSTITUTE HOT PROCESS FLUIDS FOR STEAM $2,393 $10,000 Not Implemented