IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

483

matching recommendations
Reset
ARC 2.2 Thermal Systems
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UM0393 # 12 Y:2011 12 2011 INSULATE BARE EQUIPMENT $12,938 $600 Implemented
DL0075 # 04 Y:2011 04 2011 PREHEAT COMBUSTION AIR WITH WASTE HEAT $6,900 $2,920 Not Implemented
DL0075 # 05 Y:2011 05 2011 USE "HEAT WHEEL" OR OTHER HEAT EXCHANGER TO CROSS-EXCHANGE BUILDING EXHAUST AIR WITH MAKE-UP AIR $6,900 $9,250 Not Implemented
DL0075 # 06 Y:2011 06 2011 RECOVER WASTE HEAT FROM EQUIPMENT $4,000 $5,000 Not Implemented
DL0075 # 07 Y:2011 07 2011 RECOVER WASTE HEAT FROM EQUIPMENT $3,281 $5,000 Not Implemented
OR0572 # 04 Y:2011 04 2011 INSTALL / REPAIR INSULATION ON STEAM LINES $2,350 $4,320 Implemented
OR0572 # 06 Y:2011 06 2011 PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT $8,030 $14,750 Not Implemented
MS0380 # 01 Y:2011 01 2011 REPAIR AND ELIMINATE STEAM LEAKS $19,820 $561 Not Implemented
TT0071 # 03 Y:2011 03 2011 RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR $13,100 $8,000 Not Implemented
TT0071 # 06 Y:2011 06 2011 RECOVER WASTE HEAT FROM EQUIPMENT $4,600 $3,000 Not Implemented
UM0392 # 06 Y:2011 06 2011 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $30,528 $66,561 Not Implemented
UM0392 # 07 Y:2011 07 2011 INSTALL / REPAIR INSULATION ON STEAM LINES $10,240 $13,740 Not Implemented
UM0392 # 08 Y:2011 08 2011 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $630 $1,000 Implemented
UM0390 # 02 Y:2011 02 2011 INSULATE BARE EQUIPMENT $11,887 $2,716 Not Implemented
UM0390 # 05 Y:2011 05 2011 RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER $27,012 $59,940 Not Implemented
UM0390 # 06 Y:2011 06 2011 RECOVER WASTE HEAT FROM EQUIPMENT $6,628 $5,000 Not Implemented
MA0674 # 01 Y:2011 01 2011 UTILIZE A LESS EXPENSIVE COOLING METHOD $11,498 $17,900 Not Implemented
MA0674 # 07 Y:2011 07 2011 INSULATE BARE EQUIPMENT $434 $1,400 Not Implemented
MS0379 # 01 Y:2011 01 2011 RECOVER WASTE HEAT FROM EQUIPMENT $1,001 $3,105 Not Implemented
SD0439 # 04 Y:2011 04 2011 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $5,851 $8,326 Not Implemented
SD0439 # 06 Y:2011 06 2011 RECOVER WASTE HEAT FROM EQUIPMENT $163,156 $302,600 Not Implemented
WV0434 # 01 Y:2011 01 2011 INCREASE AMOUNT OF CONDENSATE RETURNED $23,833 $46,000 Not Implemented
WV0434 # 07 Y:2011 07 2011 INSTALL / REPAIR INSULATION ON STEAM LINES $2,623 $1,025 Implemented
WV0434 # 08 Y:2011 08 2011 USE HEAT IN FLUE GASES TO PREHEAT PRODUCTS OR MATERIALS $2,596 $9,940 Not Implemented
MS0378 # 01 Y:2011 01 2011 USE HEAT IN FLUE GASES TO PREHEAT PRODUCTS OR MATERIALS $23,582 $178,700 Not Implemented