Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
592
matching recommendationsARC | 2.2 | Thermal Systems |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AM0499 # 09 Y:2005 | 09 | 2005 | USE OPTIMUM THICKNESS INSULATION | $505 | $35 | Not Implemented |
AM0499 # 10 Y:2005 | 10 | 2005 | USE OPTIMUM THICKNESS INSULATION | $270 | $40 | Not Implemented |
GT0815 # 02 Y:2005 | 02 | 2005 | REPLACE HEAT TREATING OVEN WITH MORE EFFICIENT UNIT | $84,900 | $37,500 | Not Implemented |
GT0815 # 01 Y:2005 | 01 | 2005 | RECOVER WASTE HEAT FROM EQUIPMENT | $116,700 | $90,000 | Not Implemented |
UM0294 # 06 Y:2005 | 06 | 2005 | INSULATE BARE EQUIPMENT | $1,231 | $1,344 | Not Implemented |
UM0294 # 01 Y:2005 | 01 | 2005 | COVER OPEN TANKS | $48,559 | $7,232 | Not Implemented |
OR0494 # 01 Y:2005 | 01 | 2005 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $77,000 | $0 | Not Implemented |
UU0089 # 02 Y:2005 | 02 | 2005 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $1,820 | $1,500 | Not Implemented |
UU0089 # 03 Y:2005 | 03 | 2005 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $17,940 | $21,000 | Not Implemented |
GT0811 # 06 Y:2005 | 06 | 2005 | RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR | $1,877 | $1,300 | Implemented |
GT0811 # 02 Y:2005 | 02 | 2005 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $28,824 | $20,700 | Implemented |
IC0110 # 04 Y:2005 | 04 | 2005 | REPAIR AND ELIMINATE STEAM LEAKS | $6,051 | $400 | Implemented |
GT0811 # 08 Y:2005 | 08 | 2005 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $162,720 | $25,000 | Not Implemented |
SD0374 # 05 Y:2005 | 05 | 2005 | COVER OPEN TANKS | $2,000 | $4,500 | Not Implemented |
IC0110 # 03 Y:2005 | 03 | 2005 | REPAIR OR REPLACE STEAM TRAPS | $29,831 | $1,638 | Implemented |
IC0110 # 02 Y:2005 | 02 | 2005 | SUBSTITUTE HOT PROCESS FLUIDS FOR STEAM | $79,621 | $634,572 | Not Implemented |
IC0110 # 07 Y:2005 | 07 | 2005 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $7,443 | $15,000 | Not Implemented |
WI0503 # 03 Y:2005 | 03 | 2005 | USE OPTIMUM THICKNESS INSULATION | $8,005 | $7,500 | Not Implemented |
WI0503 # 04 Y:2005 | 04 | 2005 | RECOVER WASTE HEAT FROM EQUIPMENT | $5,112 | $1,000 | Not Implemented |
GT0814 # 01 Y:2005 | 01 | 2005 | RECOVER WASTE HEAT FROM EQUIPMENT | $39,400 | $50,000 | Not Implemented |
IA0377 # 09 Y:2005 | 09 | 2005 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,898 | $2,550 | Not Implemented |
IA0377 # 07 Y:2005 | 07 | 2005 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $17,516 | $18,000 | Not Implemented |
UF0370 # 05 Y:2005 | 05 | 2005 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $43,146 | $1,190 | Not Implemented |
UF0370 # 07 Y:2005 | 07 | 2005 | INSULATE BARE EQUIPMENT | $4,053 | $1,317 | Implemented |
UF0370 # 09 Y:2005 | 09 | 2005 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $47,299 | $130,000 | Implemented |