Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

15

matching recommendations
Reset
ARC 2.26 COOLING
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MA0228 # 02 Y:1991 02 1991 USE HIGHEST TEMPERATURE FOR CHILLING OR COLD STORAGE $8,647 $5,000 Implemented
OR0132 # 03 Y:1991 03 1991 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $2,074 $500 Implemented
OR0132 # 08 Y:1991 08 1991 USE HIGHEST TEMPERATURE FOR CHILLING OR COLD STORAGE $1,040 $1,200 Implemented
OR0127 # 01 Y:1991 01 1991 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $117 $0 Implemented
MA0211 # 03 Y:1991 03 1991 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $2,122 $8,554 Implemented
OK0343 # 02 Y:1991 02 1991 USE COOLING TOWER WATER INSTEAD OF REFRIGERATION $17,827 $31,500 Implemented
RU0115 # 07 Y:1991 07 1991 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $2,041 $2,700 Implemented
MO0027 # 05 Y:1991 05 1991 USE MULTIPLE-EFFECT EVAPORATORS $978 $0 Implemented
OR0113 # 06 Y:1991 06 1991 MINIMIZE CONDENSER COOLING WATER TEMPERATURE $588 $1,500 Implemented
KU0339 # 04 Y:1991 04 1991 USE OUTSIDE COLD WATER SOURCE AS A SUPPLY OF COOLING WATER $1,066 $525 Implemented
RU0113 # 06 Y:1991 06 1991 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $17,916 $11,500 Implemented
WI0112 # 10 Y:1991 10 1991 USE OUTSIDE COLD WATER SOURCE AS A SUPPLY OF COOLING WATER $73 $0 Implemented
KU0334 # 07 Y:1991 07 1991 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $10,665 $22,600 Implemented
KU0334 # 03 Y:1991 03 1991 USE COLD WASTE WATER TO COOL CHILLER FEED WATER $22,062 $33,150 Implemented
AM0109 # 03 Y:1991 03 1991 MODERATE COOLING TOWER OUTLET TEMPERATURE $550 $0 Implemented