Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

47,292

matching recommendations
Reset
ARC 2.7 Building and Grounds
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
TN0152 # 02 Y:1982 02 1982 INSTALL TIMERS AND/OR THERMOSTATS $5,940 $0 Implemented
TN0153 # 06 Y:1982 06 1982 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $281 $2,760 Not Implemented
TN0153 # 07 Y:1982 07 1982 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $214 $108 Not Implemented
TN0155 # 01 Y:1982 01 1982 USE DIRECT AIR SUPPLY TO EXHAUST HOODS $29,118 $6,200 Not Implemented
TN0157 # 03 Y:1982 03 1982 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE $140 $64 Not Implemented
TN0136 # 03 Y:1982 03 1982 REDUCE GLAZED AREAS IN BUILDINGS $315 $1,000 Not Implemented
UD0054 # 01 Y:1982 01 1982 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,558 $872 Implemented
UD0054 # 02 Y:1982 02 1982 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE $15,588 $146,250 Implemented
UD0054 # 04 Y:1982 04 1982 INSTALL STORM WINDOWS AND DOORS $20,425 $29,798 Implemented
UD0056 # 01 Y:1982 01 1982 INSTALL STORM WINDOWS AND DOORS $773 $600 Not Implemented
UD0057 # 01 Y:1982 01 1982 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $422 $140 Not Implemented
UD0059 # 01 Y:1982 01 1982 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE $11,587 $5,000 Not Implemented
UD0059 # 02 Y:1982 02 1982 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,192 $906 Not Implemented
UD0047 # 02 Y:1982 02 1982 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,175 $122 Not Implemented
UD0047 # 05 Y:1982 05 1982 INSTALL STORM WINDOWS AND DOORS $5,066 $6,048 Not Implemented
UD0048 # 01 Y:1982 01 1982 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,576 $1,603 Not Implemented
UD0049 # 01 Y:1982 01 1982 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $2,155 $320 Implemented
UD0049 # 03 Y:1982 03 1982 REDUCE GLAZED AREAS IN BUILDINGS $28,537 $40,346 Implemented
UD0049 # 04 Y:1982 04 1982 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE $14,665 $163,485 Implemented
UD0050 # 01 Y:1982 01 1982 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,891 $396 Not Implemented
UD0050 # 04 Y:1982 04 1982 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE $1,051 $5,156 Implemented
UD0051 # 02 Y:1982 02 1982 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,295 $753 Implemented
UD0051 # 03 Y:1982 03 1982 CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS $4,219 $6,160 Implemented
UD0053 # 02 Y:1982 02 1982 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,215 $498 Not Implemented
UD0053 # 03 Y:1982 03 1982 REDUCE GLAZED AREAS IN BUILDINGS $4,533 $5,752 Not Implemented