Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
47,484
matching recommendationsARC | 2.7 | Building and Grounds |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0380 # 05 Y:2008 | 05 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,310 | $0 | Implemented |
WV0380 # 08 Y:2008 | 08 | 2008 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $3,853 | $13,200 | Not Implemented |
TT0023 # 01 Y:2008 | 01 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $21,401 | $13,400 | Not Implemented |
TT0023 # 02 Y:2008 | 02 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $18,785 | $23,530 | Not Implemented |
TT0023 # 03 Y:2008 | 03 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,700 | $11,100 | Not Implemented |
TT0023 # 04 Y:2008 | 04 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,685 | $7,344 | Not Implemented |
UD0786 # 01 Y:2008 | 01 | 2008 | AIR CONDITION ONLY SPACE NECESSARY | $33,340 | $66,680 | Implemented |
UD0786 # 02 Y:2008 | 02 | 2008 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $16,751 | $15,000 | Implemented |
UD0786 # 03 Y:2008 | 03 | 2008 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $8,467 | $5,000 | Implemented |
UD0786 # 04 Y:2008 | 04 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,109 | $9,240 | Implemented |
UD0786 # 07 Y:2008 | 07 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,608 | $5,812 | Not Implemented |
UD0786 # 08 Y:2008 | 08 | 2008 | INSTALL REPLACEMENT DOORS | $1,292 | $7,600 | Not Implemented |
OK0767 # 02 Y:2008 | 02 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $14,151 | $34,635 | Not Implemented |
OK0767 # 03 Y:2008 | 03 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $803 | $3,455 | Not Implemented |
OK0767 # 04 Y:2008 | 04 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,640 | $7,796 | Not Implemented |
OK0767 # 06 Y:2008 | 06 | 2008 | USE RADIANT HEATER FOR SPOT HEATING | $81,407 | $117,000 | Not Implemented |
OK0767 # 07 Y:2008 | 07 | 2008 | INSTALL TIMERS AND/OR THERMOSTATS | $46,431 | $6,300 | Implemented |
IA0429 # 05 Y:2008 | 05 | 2008 | INSTALL SPECTRAL REFLECTORS / DELAMP | $460 | $68 | Not Implemented |
IA0429 # 06 Y:2008 | 06 | 2008 | INSTALL OCCUPANCY SENSORS | $1,353 | $2,424 | Implemented |
IA0429 # 09 Y:2008 | 09 | 2008 | USE RADIANT HEATER FOR SPOT HEATING | $1,842 | $25,870 | Implemented |
IC0143 # 01 Y:2008 | 01 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,805 | $14,430 | Not Implemented |
IC0143 # 02 Y:2008 | 02 | 2008 | DISCONNECT BALLASTS | $26 | $26 | Implemented |
IC0143 # 03 Y:2008 | 03 | 2008 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $338 | $0 | Implemented |
IC0143 # 04 Y:2008 | 04 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $944 | $162 | Implemented |
IC0143 # 05 Y:2008 | 05 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $90 | $142 | Implemented |