Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,203
matching recommendationsARC | 2.7 | Building and Grounds |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UW2209 # 04 Y:2022 | 04 | 2022 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $2,276 | $0 | Implemented |
CI0004 # 02 Y:2022 | 02 | 2022 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $33,110 | $75,225 | Not Implemented |
CI0004 # 03 Y:2022 | 03 | 2022 | USE PHOTOCELL CONTROLS | $8,537 | $4,050 | Not Implemented |
CI0004 # 05 Y:2022 | 05 | 2022 | SEPARATE CONTROLS OF AIR HANDLERS FROM AC/ HEATING SYSTEMS | $4,787 | $8,000 | Not Implemented |
CI0004 # 06 Y:2022 | 06 | 2022 | INSTALL OCCUPANCY SENSORS | $1,464 | $2,000 | Not Implemented |
IP0163 # 03 Y:2022 | 03 | 2022 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $1,306 | $3 | Implemented |
IP0163 # 04 Y:2022 | 04 | 2022 | USE PHOTOCELL CONTROLS | $2,682 | $248 | Implemented |
TR0028 # 01 Y:2022 | 01 | 2022 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,361 | $5,404 | Not Implemented |
TR0028 # 03 Y:2022 | 03 | 2022 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $7,119 | $11,200 | Not Implemented |
CI0003 # 01 Y:2022 | 01 | 2022 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $87,136 | $114,800 | n/a |
CI0003 # 06 Y:2022 | 06 | 2022 | USE PHOTOCELL CONTROLS | $3,744 | $1,166 | n/a |
SU0523 # 01 Y:2022 | 01 | 2022 | DISCONNECT BALLASTS | $4,994 | $0 | Not Implemented |
SU0523 # 02 Y:2022 | 02 | 2022 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,899 | $250 | Not Implemented |
SU0523 # 05 Y:2022 | 05 | 2022 | INSTALL OCCUPANCY SENSORS | $652 | $567 | Not Implemented |
SU0523 # 08 Y:2022 | 08 | 2022 | REDUCE VENTILATION AIR | $346 | $1,265 | Not Implemented |
UA0262 # 01 Y:2022 | 01 | 2022 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $46,023 | $44,464 | Implemented |
UA0262 # 02 Y:2022 | 02 | 2022 | INSTALL OCCUPANCY SENSORS | $2,699 | $2,060 | Implemented |
CM1006 # 03 Y:2022 | 03 | 2022 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $454 | $25 | Not Implemented |
CM1006 # 04 Y:2022 | 04 | 2022 | INSTALL HEAT PIPES / RAISE COOLING SETPOINT | $118 | $0 | Implemented |
CM1006 # 07 Y:2022 | 07 | 2022 | LOWER LIGHT FIXTURES IN HIGH CEILING AREAS | $29,546 | $160,998 | Implemented |
ORC005 # 01 Y:2022 | 01 | 2022 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,739 | $21,350 | Not Implemented |
ORC005 # 02 Y:2022 | 02 | 2022 | INSTALL OCCUPANCY SENSORS | $1,887 | $2,000 | Not Implemented |
ORC005 # 03 Y:2022 | 03 | 2022 | INSTALL TIMERS AND/OR THERMOSTATS | $1,949 | $15,000 | Not Implemented |
UD1048 # 01 Y:2022 | 01 | 2022 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $15,150 | $1,500 | Not Implemented |
UD1048 # 02 Y:2022 | 02 | 2022 | INSTALL OCCUPANCY SENSORS | $1,915 | $625 | Not Implemented |