Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

1,224

matching recommendations
Reset
ARC 2.7 Building and Grounds
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
SU0147 # 02 Y:2002 02 2002 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $4,126 $7,590 Not Implemented
SU0147 # 08 Y:2002 08 2002 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $694 $196 Not Implemented
UU0029 # 03 Y:2002 03 2002 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $15,840 $8,250 Not Implemented
UU0029 # 05 Y:2002 05 2002 PLANT TREES OR SHRUBS NEAR WINDOWS TO SHIELD FROM SUNLIGHT $229 $1,650 Not Implemented
IA0305 # 04 Y:2002 04 2002 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,039 $10,736 Not Implemented
IA0305 # 05 Y:2002 05 2002 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,826 $0 Not Implemented
AM0420 # 09 Y:2002 09 2002 USE PHOTOCELL CONTROLS $1,500 $2,300 Implemented
MS0216 # 06 Y:2002 06 2002 INSTALL TIMERS AND/OR THERMOSTATS $231 $472 Implemented
MS0216 # 07 Y:2002 07 2002 DISCONNECT BALLASTS $44 $66 Implemented
MI0050 # 02 Y:2002 02 2002 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $95,397 $66,000 Not Implemented
MI0050 # 03 Y:2002 03 2002 INSTALL OR UPGRADE INSULATION ON HVAC DISTRIBUTION SYSTEMS $53,360 $5,000 Not Implemented
MI0050 # 04 Y:2002 04 2002 INSTALL SPECTRAL REFLECTORS / DELAMP $10,046 $21,150 Not Implemented
BD0218 # 02 Y:2002 02 2002 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,615 $4,950 Not Implemented
BD0218 # 04 Y:2002 04 2002 INSTALL OCCUPANCY SENSORS $2,415 $2,175 Not Implemented
BD0218 # 06 Y:2002 06 2002 USE RADIANT HEATER FOR SPOT HEATING $2,060 $6,000 Not Implemented
BD0218 # 09 Y:2002 09 2002 USE PHOTOCELL CONTROLS $1,082 $750 Not Implemented
BD0218 # 12 Y:2002 12 2002 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $492 $409 Not Implemented
AM0422 # 04 Y:2002 04 2002 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $780 $50 Implemented
AM0422 # 07 Y:2002 07 2002 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $345 $310 Implemented
SD0308 # 02 Y:2002 02 2002 VENTILATION SYSTEM TO SHUT OFF WHEN ROOM IS NOT IN USE $7,470 $6,000 Not Implemented
SD0308 # 04 Y:2002 04 2002 VENTILATION SYSTEM TO SHUT OFF WHEN ROOM IS NOT IN USE $1,853 $0 Not Implemented
SD0308 # 05 Y:2002 05 2002 USE PHOTOCELL CONTROLS $525 $500 Not Implemented
TA0039 # 01 Y:2002 01 2002 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $49,940 $0 Implemented
TA0039 # 03 Y:2002 03 2002 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $6,515 $0 Implemented
TA0039 # 05 Y:2002 05 2002 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT $6,290 $0 Implemented