Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
28
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OR0576 # 01 Y:2011 | 01 | 2011 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $10,860 | $1,000 | Implemented |
OR0575 # 03 Y:2011 | 03 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,748 | $3,023 | Implemented |
OR0575 # 04 Y:2011 | 04 | 2011 | INSTALL / REPAIR INSULATION ON STEAM LINES | $3,389 | $948 | Implemented |
OR0574 # 02 Y:2011 | 02 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,450 | $7,166 | Implemented |
OR0573 # 05 Y:2011 | 05 | 2011 | INSTALL / REPAIR INSULATION ON STEAM LINES | $11,543 | $7,806 | Implemented |
OR0572 # 07 Y:2011 | 07 | 2011 | ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS | $1,280 | $500 | Implemented |
OR0572 # 04 Y:2011 | 04 | 2011 | INSTALL / REPAIR INSULATION ON STEAM LINES | $2,350 | $4,320 | Implemented |
OR0572 # 01 Y:2011 | 01 | 2011 | UPGRADE CONTROLS ON COMPRESSORS | $6,860 | $3,642 | Implemented |
OR0570 # 01 Y:2011 | 01 | 2011 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $19,863 | $1,120 | Implemented |
OR0571 # 06 Y:2011 | 06 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $15,292 | $44,400 | Implemented |
OR0571 # 04 Y:2011 | 04 | 2011 | INSTALL ADEQUATE DRYERS ON AIR LINES TO ELIMINATE BLOWDOWN | $1,906 | $7,000 | Implemented |
OR0571 # 03 Y:2011 | 03 | 2011 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,616 | $2,200 | Implemented |
OR0571 # 02 Y:2011 | 02 | 2011 | UPGRADE CONTROLS ON COMPRESSORS | $13,809 | $52,890 | Implemented |
OR0569 # 04 Y:2011 | 04 | 2011 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $517 | $517 | Implemented |
OR0569 # 05 Y:2011 | 05 | 2011 | INSTALL OCCUPANCY SENSORS | $17,900 | $58,500 | Implemented |
OR0569 # 02 Y:2011 | 02 | 2011 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $5,650 | $700 | Implemented |
OR0569 # 01 Y:2011 | 01 | 2011 | USE OPTIMUM TEMPERATURE | $9,149 | $450 | Implemented |
OR0567 # 06 Y:2011 | 06 | 2011 | INSULATE BARE EQUIPMENT | $1,248 | $2,547 | Implemented |
OR0567 # 05 Y:2011 | 05 | 2011 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $12,000 | $5,580 | Implemented |
OR0567 # 01 Y:2011 | 01 | 2011 | ADD/MODIFY EQUIPMENT TO IMPROVE DRYING PROCESS | $2,000 | $1,510 | Implemented |
OR0566 # 03 Y:2011 | 03 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,690 | $1,690 | Implemented |
OR0566 # 02 Y:2011 | 02 | 2011 | INSTALL OCCUPANCY SENSORS | $4,340 | $9,990 | Implemented |
OR0566 # 01 Y:2011 | 01 | 2011 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $3,230 | $635 | Implemented |
OR0565 # 01 Y:2011 | 01 | 2011 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $14,900 | $9,340 | Implemented |
OR0565 # 03 Y:2011 | 03 | 2011 | RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR | $10,300 | $17,700 | Implemented |