Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,392
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SD0191 # 01 Y:1998 | 01 | 1998 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $4,838 | $5,890 | Implemented |
SD0191 # 06 Y:1998 | 06 | 1998 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $18,900 | $8,500 | Implemented |
SD0191 # 08 Y:1998 | 08 | 1998 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $12,650 | $0 | Implemented |
SD0191 # 09 Y:1998 | 09 | 1998 | TREAT AND REUSE RINSE WATERS | $654 | $750 | Implemented |
SD0190 # 01 Y:1998 | 01 | 1998 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $7,869 | $11,580 | Implemented |
SD0190 # 05 Y:1998 | 05 | 1998 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $8,620 | $1,350 | Implemented |
SD0190 # 06 Y:1998 | 06 | 1998 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $4,072 | $0 | Implemented |
SD0190 # 09 Y:1998 | 09 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,443 | $6,942 | Implemented |
SD0190 # 10 Y:1998 | 10 | 1998 | INSTALL SPECTRAL REFLECTORS / DELAMP | $2,302 | $2,150 | Implemented |
SD0190 # 11 Y:1998 | 11 | 1998 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $9,500 | $9,000 | Implemented |
SD0189 # 01 Y:1998 | 01 | 1998 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $23,155 | $22,250 | Implemented |
SD0189 # 04 Y:1998 | 04 | 1998 | USE OPTIMUM THICKNESS INSULATION | $678 | $219 | Implemented |
SD0189 # 05 Y:1998 | 05 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,587 | $5,358 | Implemented |
SD0189 # 07 Y:1998 | 07 | 1998 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $5,780 | $8,500 | Implemented |
SD0188 # 02 Y:1998 | 02 | 1998 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $6,284 | $0 | Implemented |
SD0188 # 03 Y:1998 | 03 | 1998 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $807 | $405 | Implemented |
SD0188 # 04 Y:1998 | 04 | 1998 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $7,100 | $8,500 | Implemented |
SD0187 # 01 Y:1998 | 01 | 1998 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $2,309 | $3,660 | Implemented |
SD0187 # 02 Y:1998 | 02 | 1998 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,982 | $500 | Implemented |
SD0187 # 03 Y:1998 | 03 | 1998 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,566 | $0 | Implemented |
SD0187 # 04 Y:1998 | 04 | 1998 | INSTALL TIMERS AND/OR THERMOSTATS | $1,433 | $2,400 | Implemented |
SD0186 # 01 Y:1998 | 01 | 1998 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,357 | $3,530 | Implemented |
SD0186 # 04 Y:1998 | 04 | 1998 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,973 | $500 | Implemented |
SD0186 # 05 Y:1998 | 05 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $928 | $1,853 | Implemented |
SD0186 # 06 Y:1998 | 06 | 1998 | INSTALL SPECTRAL REFLECTORS / DELAMP | $2,785 | $5,115 | Implemented |