Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
3,509
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0777 # 07 Y:2008 | 07 | 2008 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $35,347 | $15,000 | Implemented |
UD0777 # 08 Y:2008 | 08 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $33,252 | $1,000 | Implemented |
UD0777 # 12 Y:2008 | 12 | 2008 | COOL COMPRESSOR AIR INTAKE WITH HEAT EXCHANGER | $8,318 | $19,000 | Implemented |
UD0777 # 13 Y:2008 | 13 | 2008 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $4,240 | $0 | Implemented |
UD0777 # 14 Y:2008 | 14 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,509 | $3,815 | Implemented |
UD0776 # 02 Y:2008 | 02 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $48,929 | $1,000 | Implemented |
UD0776 # 06 Y:2008 | 06 | 2008 | USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING | $30,220 | $0 | Implemented |
UD0775 # 01 Y:2008 | 01 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $690 | $2,738 | Implemented |
UD0775 # 02 Y:2008 | 02 | 2008 | INSTALL AUTOMATIC STACK DAMPER | $650 | $400 | Implemented |
UD0775 # 05 Y:2008 | 05 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $343 | $300 | Implemented |
UD0775 # 08 Y:2008 | 08 | 2008 | USE DOUBLE OR TRIPLE GLAZED WINDOWS TO MAINTAIN HIGHER RELATIVE HUMIDITY AND TO REDUCE HEAT LOSSES | $95 | $0 | Implemented |
UD0775 # 09 Y:2008 | 09 | 2008 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $82 | $0 | Implemented |
UD0774 # 02 Y:2008 | 02 | 2008 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $94,656 | $6,000 | Implemented |
UD0774 # 03 Y:2008 | 03 | 2008 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $83,440 | $5,000 | Implemented |
UD0774 # 05 Y:2008 | 05 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $9,705 | $3,275 | Implemented |
UD0774 # 06 Y:2008 | 06 | 2008 | INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS | $9,454 | $0 | Implemented |
UD0774 # 10 Y:2008 | 10 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,371 | $2,250 | Implemented |
UD0774 # 11 Y:2008 | 11 | 2008 | USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE | $3,078 | $0 | Implemented |
UD0773 # 01 Y:2008 | 01 | 2008 | UPGRADE CONTROLS ON COMPRESSORS | $79,805 | $20,000 | Implemented |
UD0773 # 03 Y:2008 | 03 | 2008 | ENHANCE SENSITIVITY OF TEMPERATURE CONTROL AND CUTOFF | $22,200 | $15,000 | Implemented |
UD0773 # 07 Y:2008 | 07 | 2008 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $9,990 | $0 | Implemented |
UD0772 # 01 Y:2007 | 01 | 2007 | MODIFY STARTUP/SHUTDOWN TIMES | $144,431 | $0 | Implemented |
UD0772 # 02 Y:2007 | 02 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $37,082 | $161,076 | Implemented |
UD0772 # 07 Y:2007 | 07 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $10,540 | $58,765 | Implemented |
UD0772 # 08 Y:2007 | 08 | 2007 | UPGRADE CONTROLS ON COMPRESSORS | $7,421 | $17,000 | Implemented |