Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
4,631
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0579 # 06 Y:1999 | 06 | 1999 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $910 | $0 | Implemented |
UD0578 # 01 Y:1999 | 01 | 1999 | INSTALL SHELVES / RACKS TO UTILIZE UNUSED SPACE | $323,997 | $26,940 | Implemented |
UD0578 # 03 Y:1999 | 03 | 1999 | INSTALL EQUIPMENT TO MOVE PRODUCT | $19,500 | $8,600 | Implemented |
UD0578 # 04 Y:1999 | 04 | 1999 | USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS | $17,671 | $3,000 | Implemented |
UD0578 # 06 Y:1999 | 06 | 1999 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $5,242 | $0 | Implemented |
UM0147 # 05 Y:1999 | 05 | 1999 | RECOVER AND REUSE WASTE MATERIAL | $1,436 | $0 | Implemented |
UD0576 # 03 Y:1999 | 03 | 1999 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $10,377 | $4,700 | Implemented |
UD0576 # 06 Y:1999 | 06 | 1999 | USE COUNTER CURRENT RINSING TO REDUCE WASTE WATER | $1,407 | $1,000 | Implemented |
UD0575 # 03 Y:1999 | 03 | 1999 | MINIMIZE OPERATION OF EQUIPMENT MAINTAINED IN STANDBY CONDITION | $39,515 | $10,000 | Implemented |
UD0575 # 04 Y:1999 | 04 | 1999 | RECOVER WASTE HEAT FROM EQUIPMENT | $14,341 | $15,000 | Implemented |
UD0574 # 04 Y:1999 | 04 | 1999 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $5,572 | $0 | Implemented |
UD0573 # 01 Y:1999 | 01 | 1999 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $238,622 | $0 | Implemented |
UD0573 # 02 Y:1999 | 02 | 1999 | RECYCLE CASTING SAND | $159,120 | $310,000 | Implemented |
UD0573 # 05 Y:1999 | 05 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,523 | $14,669 | Implemented |
UD0572 # 02 Y:1999 | 02 | 1999 | USE PLASTIC PALLETS INSTEAD OF WOOD | $38,960 | $110,457 | Implemented |
UD0572 # 04 Y:1999 | 04 | 1999 | INSTALL SPECTRAL REFLECTORS / DELAMP | $9,457 | $-27,115 | Implemented |
UD0571 # 01 Y:1999 | 01 | 1999 | RECYCLE CASTING SAND | $227,844 | $135,000 | Implemented |
UD0571 # 04 Y:1999 | 04 | 1999 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $21,000 | $64,000 | Implemented |
UD0571 # 08 Y:1999 | 08 | 1999 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $5,582 | $0 | Implemented |
UD0570 # 01 Y:1999 | 01 | 1999 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $27,963 | $0 | Implemented |
UD0570 # 03 Y:1999 | 03 | 1999 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $4,148 | $200 | Implemented |
UD0569 # 02 Y:1999 | 02 | 1999 | INCREASE USE OF AUTOMATION | $65,250 | $0 | Implemented |
UD0569 # 05 Y:1999 | 05 | 1999 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $6,848 | $632 | Implemented |
UD0568 # 03 Y:1999 | 03 | 1999 | CHANGE ZONE REHEAT COILS TO VARIABLE AIR VOLUME BOXES | $5,171 | $4,000 | Implemented |
UD0567 # 01 Y:1999 | 01 | 1999 | INSTALL AUTOMATIC PACKING EQUIPMENT | $1,501,920 | $1,075,000 | Implemented |